Platform-specific comparison of IMRT and VMAT angular resolution for Ethos-based online adaptive radiotherapy in cervical cancer.
Xiangyue Kong, Bin Zhang, Gongsen Zhang, Haonan Xiao
Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China. · Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, China.
Key points
From the paper's conclusion- On the Ethos platform, the IMRT technique offers a favorable balance for cervical cancer oART, combining superior target homogeneity, improved rectum, bladder, and bone marrow sparing, lower bowel D2cc, and rapid plan generation that minimizes the critical scan-to-beam interval. However, bowel V30 was lower with VMAT, suggesting that bowel sparing depends on the selected dose-volume metric.
Abstract
BACKGROUND: The Ethos™ platform enables online adaptive radiotherapy (oART) to mitigate inter-fractional anatomical variations. However, the lengthy "scan-to-beam" workflow introduces the risk of intra-fractional motion. This study aimed to investigate the dosimetric and efficiency differences between IMRT and VMAT with varying angular resolutions, providing data to guide the selection of planning strategies in Ethos-based oART. MATERIALS AND METHODS: Fifteen patients with cervical cancer treated on the Ethos platform were retrospectively analyzed. For each patient, five plans were generated: a standard 9-field IMRT plan and four VMAT plans optimized with angular resolutions of 2°, 3°, 4°, and 5° (VMAT2-VMAT5). Dosimetric metrics for Planning Target Volume (PTV) and Organs at Risk (OARs), along with plan generation efficiency (optimization and calculation time), delivery efficiency (beam-on and total delivery time), and deliverability (gamma analysis), were systematically evaluated. RESULTS: All plans met clinical requirements. IMRT demonstrated superior dose homogeneity (HI: 0.07 ± 0.01) compared to all VMAT groups (0.09-0.10, P< 0.001). For OARs, IMRT provided better sparing of the rectum, bladder, and bone marrow, and reduced the high-dose bowel metric D2cc; however, bowel V30 was lower in the VMAT groups, indicating metric-dependent bowel sparing. In terms of efficiency, IMRT required substantially shorter optimization time (122.8 ± 14.6 s) than VMAT (705.9-742.9 s, P< 0.001). Conversely, VMAT reduced the total delivery time by approximately 50% compared to IMRT (158.1 s vs. 305.3 s, P< 0.001). Among VMAT plans, finer resolutions (2°-3°) offered slight dosimetric advantages over coarser resolutions (4°-5°) but required longer calculation times. Gamma passing rates were >98% (3%/3mm) for all techniques, with IMRT showing marginally higher accuracy. CONCLUSION: On the Ethos platform, the IMRT technique offers a favorable balance for cervical cancer oART, combining superior target homogeneity, improved rectum, bladder, and bone marrow sparing, lower bowel D2cc, and rapid plan generation that minimizes the critical scan-to-beam interval. However, bowel V30 was lower with VMAT, suggesting that bowel sparing depends on the selected dose-volume metric.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dosimetric Validation of Ethos Online Adaptive Radiotherapy for Prostate Cancer: An End-to-End Phantom Study.Life (Basel, Switzerland) · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Toward optimal radiotherapy in tongue cancer: a comparative study of IMRT and VMAT.Radiological physics and technology · 2026
- Exploring a hybrid workflow on current adaptive radiotherapy systems.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Moderately Hypofractionated Online Adaptive Radiotherapy for Cervical Cancer: A Prospective Study of Feasibility, Acute Toxicity and Dosimetric Benefits.Cancers · 2026
- Strategic planning approaches to optimize volumetric modulated arc therapy for locoregional breast irradiation.Radiation and environmental biophysics · 2026