Comparative Dosimetric Evaluation of Tomotherapy with a 1-cm Field Width versus Volumetric-modulated Arc Therapy for Whole-brain Radiotherapy with Hippocampal Avoidance.
Sankar Sekar, R Leel Malar, A Dinesh Babu, Ezhil Sindhanai M Parvath, Muthiah Kasi, M Sai Pranav, Saravana Kumar Adhimoolam
Department of Medical Physics, PSG Hospitals, Coimbatore, Tamil Nadu, India. · Department of Radiation Oncology, PSG Hospitals, Coimbatore, Tamil Nadu, India.
Key points
From the paper's conclusion- Tomotherapy with a 1-cm field width provides superior hippocampal sparing, plan quality, and OAR protection while maintaining equivalent target coverage. VMAT achieves substantially faster treatment delivery with fewer MU, offering an alternative when shorter treatment times are preferred.
Abstract
BACKGROUND: Hippocampal-avoidance whole-brain radiotherapy (HA-WBRT) reduces radiation dose to the hippocampal neural stem-cell niche, helping preserve neurocognitive function in patients with brain metastases. OBJECTIVE: The objective of this study is to compare tomotherapy using a 1-cm field width with four-arc volumetric-modulated arc therapy (VMAT) for HA-WBRT. MATERIALS AND METHODS: Twenty patients prescribed 30 Gy in 10 fractions were planned on both platforms. Hippocampi were contoured on T1-weighted magnetic resonance imaging according to the RTOG 0933 atlas. Tomotherapy plans used a 1-cm jaw, pitch 0.500, and modulation factor 1.5-2.0, while VMAT plans used 6 MV photons with one coplanar and three noncoplanar arcs. Plan quality, hippocampal and organ-at-risk (OAR) doses, treatment efficiency, and deliverability (3%/3 mm gamma analysis) were compared. RESULTS: Planning target volume coverage was comparable (V95%: 96.67% ± 0.57% vs. 96.53% ± 0.73%; P = 0.28). Tomotherapy achieved superior homogeneity and conformity (both P < 0.001), with significantly lower hippocampal Dmax, Dmean, D40%, V10 Gy, and bilateral lens and globe doses (all P < 0.001). Gamma pass rates exceeded 95% for both techniques. VMAT provided shorter beam-on time (2.62 ± 0.25 vs. 12.21 ± 0.99 min) and lower monitor units (MU) (786.5 ± 74.9 vs. 12440.5 ± 992.9; both P < 0.001). CONCLUSION: Tomotherapy with a 1-cm field width provides superior hippocampal sparing, plan quality, and OAR protection while maintaining equivalent target coverage. VMAT achieves substantially faster treatment delivery with fewer MU, offering an alternative when shorter treatment times are preferred.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gradient partial-overlap three-arc VMAT for hippocampal-avoidance whole-brain radiotherapy: a dosimetric and robustness trade-off analysis.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A Dosimetric and Biological Comparison of Volumetric Modulated Arc Therapy and Adaptive Aperture Proton Therapy for Hippocampal-Sparing Whole-Brain Radiotherapy.Technology in cancer research & treatment · 2026
- Planning evaluation of 3 photon techniques for hippocampus and scalp sparing WBRT with simultaneous integrated boost in multiple metastases.Medicine · 2026
- Unilateral vs Bilateral Hippocampal Avoidance During WBRT With Memantine for Brain Metastases: A Randomized Single-Blind Phase 2 Clinical Trial.Neuro-oncology · 2026
- Dosimetric comparison of automated noncoplanar volumetric-modulated arc therapy and intensity-modulated proton therapy for total scalp irradiation in angiosarcoma of the scalp.The British journal of radiology · 2026
- Hippocampal Brain Metastases Treatment With Whole Brain Radiotherapy or Stereotactic Radiosurgery: A First Single Center Experience.Anticancer research · 2026