American Journal of Clinical Pathology

41 Reference Interval Evolution: Why Expanding to the 99th Percentile Matters in Modern Laboratory Testing

Jillian Kodger, Joe El-Khoury

Key points

From the paper's conclusion
  • Expanding RIs to the central 99% may represent a data‑driven strategy to reduce false positives, improve post‑test interpretability of multi‑analyte panels, and better align laboratory reporting with contemporary principles of diagnostic stewardship in practice today.

Abstract

The use of the central 95% reference interval (RI) in medicine originates from 19th‑century astronomical statistics and was adopted to define physiologic “normality,” despite ongoing debate regarding its clinical relevance. In contemporary practice, particularly wellness testing and routine outpatient screening, the pre‑test probability of disease for most comprehensive metabolic panel (CMP) analytes is low, making abnormal results more likely to reflect statistical variation than true pathology. Because RIs include only 95% of a healthy population, approximately 5% of healthy individuals will fall outside the interval by definition. When multiple analytes are measured simultaneously, as in a CMP, the probability of at least one abnormal result increases substantially, such that nearly half of patients undergoing CMP testing will have at least one flagged value. In low–pre‑test‑probability populations, these abnormalities frequently represent false positives, contributing to unnecessary follow‑up testing, overdiagnosis, and patient anxiety. To evaluate what central 99%‑derived RIs for a CMP might look like, we analyzed laboratory data from 23,422 unique outpatients aged ≥18 years tested at our institution between September 1 and September 29, 2025. The cohort was 42.8% male and 57.1% female, with a median age of 63 years (IQR 18–105). CMP testing was performed on Roche Cobas instruments. Current RIs were primarily based on manufacturer package inserts, which often reflect historical methodologies and may not align with contemporary outpatient populations. These manufacturer intervals were compared with RIs derived using RefineR for both the 95th and 99th percentiles. For each analyte, bootstrap resampling was used to compute RIs and corresponding 95% confidence intervals. Clinically meaningful differences were observed between manufacturer RIs and those derived from retrospective outpatient data, notably for total protein, potassium, creatinine, AST, ALP, and BUN. For potassium, the manufacturer RI of 3.5–5.1 mmol/L widened to 3.6–5.2 mmol/L using the central 95% and to 3.4–5.5 mmol/L using the central 99%, substantially reducing abnormal flagging in otherwise healthy individuals. A similar pattern was observed for total protein, with the manufacturer RI of 6.0–8.0 g/dL expanding to 6.1–8.1 g/dL (95%) and 5.8–8.5/dL (99%). Lastly, for sodium, the manufacturer RI of 136–144 mmol/L expanded to 136–144 mmol/L using the central 95% and to 134–145 mmol/L using the central 99%. This analysis highlights the need to reassess RIs derived decades ago and contextualizing them within modern testing paradigms characterized by high-test volumes and low pre‑test probability. Expanding RIs to the central 99% may represent a data‑driven strategy to reduce false positives, improve post‑test interpretability of multi‑analyte panels, and better align laboratory reporting with contemporary principles of diagnostic stewardship in practice today.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers