Clinica chimica acta; international journal of clinical chemistry

LabRI: A data-source-agnostic, multi-method statistical consensus framework for laboratory reference interval estimation.

Alan Carvalho Dias, Luisane Maria Falci Vieira, Derliane de Oliveira, Claudia Maria Meira Dias, João Rodrigo Campos, Daniane Grando Remor Canalli, Tatiana Ferreira de Almeida, Adâmara Felício

Sabin Diagnóstico e Saúde, Brasília, Federal District, Brazil; Reference Intervals Committee of the Brazilian Society of Clinical Pathology/Laboratory Medicine (SBPC/ML), Brazil; Quality Committee of the Brazilian Society of Clinical Pathology/Laboratory Medicine (SBPC/ML), Brazil. Electronic address: alancdias@hotmail.com. · Álvaro Apoio-Grupo Dasa, São Paulo, SP, Brazil; Quality Committee of the Brazilian Society of Clinical Pathology/Laboratory Medicine (SBPC/ML), Brazil; Artificial Intelligence Committee of the Brazilian Society of Clinical Pathology/Laboratory Medicine (SBPC/ML), Brazil.

Computational

Key points

From the paper's conclusion
  • LabRI showed the closest overall agreement with the adopted comparative references across the evaluated datasets, suggesting that multi-method consensus may reduce reliance on single-estimator assumptions. Appropriate data curation and clinical plausibility review remain essential for practical application.

Abstract

BACKGROUND AND OBJECTIVE: Reference intervals (RIs) are essential for interpreting clinical laboratory results; their verification is required under ISO 15189 standards. No single estimation method is consistently accurate across distributions, sample sizes, and contamination levels. This study introduces LabRI (Laboratory Reference Interval), a data-source-agnostic multi-method consensus framework, benchmarked against Truncated Minimum Chi-square (TMC), Truncated Maximum Likelihood (TML), refineR, and reflimR. METHODS: LabRI is an R/Shiny application integrating modified refineR, reflimR, a nonparametric percentile procedure for low-count datasets, and Expectation-Maximization with Gaussian Mixture Modeling. Real-world data (Group 1) comprised 12 analytes with directly established RIs; simulated data (Group 2) comprised refineR testcase1, testcase2, and testcase4 across five subsample sizes each. Performance was assessed using Performance Ranking by Index of Deviation of Reference Limits (PRIDe-RL), prioritizing conformity with equivalence intervals (EIs) and incorporating proximity, tail behavior, and severity. Statistical uncertainty was assessed using ratios of model-based 90% confidence interval widths to RI widths (WCI/WRI). RESULTS: LabRI ranked first in both groups and overall. Its pooled PRIDe-RL score was 0.925, followed by reflimR (0.793), TMC (0.792), refineR (0.737), and TML (0.646). LabRI placed 50/54 reference limits (92.6%) within their EIs, comprising 24/24 in Group 1 and 26/30 in Group 2. No LabRI deviation exceeded twice the permissible difference. Only the upper reference limit for thyroid-stimulating hormone exceeded the predefined uncertainty threshold (WCI/WRI = 0.234; target <0.20). CONCLUSIONS: LabRI showed the closest overall agreement with the adopted comparative references across the evaluated datasets, suggesting that multi-method consensus may reduce reliance on single-estimator assumptions. Appropriate data curation and clinical plausibility review remain essential for practical application.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers