B-290 Is Hypomagnesemia in Older Adults Being Systematically Underdiagnosed? A Reference Interval Impact Study
Luisa Petrola Bezerra Sayao, Rachel Petrola, Adria Dos Santos
Key points
From the paper's conclusion- These findings reinforce the need for laboratory-driven RI harmonization strategies aligned with ISO 15189 and supported by real-world data.
Abstract
Background Magnesium is a key electrolyte in neuromuscular, cardiovascular, and metabolic regulation, yet it remains underrecognized and is often described as the “forgotten electrolyte.” Hypomagnesemia affects 3–10% of the global population and is likely underdiagnosed in older adults. Variability in laboratory reference intervals (RIs)—frequently adopted from manufacturer inserts without local validation—may contribute to this underdiagnosis. Although ISO 15189:2012 recommends establishing or verifying RIs according to the local population, this practice is not consistently implemented. This study evaluated how different RIs influence the estimated prevalence of hypomagnesemia in outpatients aged over 60 years. Methods A total of 61,750 serum magnesium measurements from outpatients aged >60 years were retrieved from the laboratory database of a private clinical laboratory in Fortaleza, Brazil, between 2022 and 2024. Individuals reporting magnesium supplementation were excluded. Reference intervals were determined using median and interquartile range analysis (DataR software). Hypomagnesemia prevalence was calculated using three lower cut-offs: (1) 1.3 mg/dL (manufacturer insert, Advia 1800 – Siemens); (2) 1.7 mg/dL (Clinical Chemistry and Laboratory Medicine, 2023, and New England Journal of Medicine, 2024); and (3) 1.6 mg/dL (locally derived RI). Statistical comparisons were performed using Wilcoxon, chi-square, and Fisher’s exact tests, with significance set at p<0.001. Results Among 61,750 individuals, 34.0% were men (n=20,997) and 66.0% were women (n=40,753). Mean serum magnesium levels were 1.99 mg/dL in men and 2.00 mg/dL in women. The prevalence of hypomagnesemia varied markedly according to the reference interval applied: 0.44% (n=277) using the manufacturer cut-off (1.3 mg/dL); 6.79% (n=4,193) using the literature-based threshold (1.7 mg/dL); and 5.02% (n=3,105) using the locally derived cut-off (1.6 mg/dL). Adoption of the literature-supported threshold resulted in a more than 15-fold increase in detected prevalence compared with the manufacturer-provided RI (p<0.001). Conclusion Reference interval selection profoundly influences the estimated prevalence of hypomagnesemia in older adults. Manufacturer-provided RIs may substantially underestimate clinically relevant magnesium deficiency. Implementing literature-supported or locally verified RIs markedly increases detection and may reduce underdiagnosis in a population particularly vulnerable to electrolyte disturbances. These findings reinforce the need for laboratory-driven RI harmonization strategies aligned with ISO 15189 and supported by real-world data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Identifying High-Yield Groups for the Detection of Low Serum Magnesium in Diabetes: A Nationally Representative Study of Korean Adults.Journal of clinical medicine · 2026
- 41 Reference Interval Evolution: Why Expanding to the 99th Percentile Matters in Modern Laboratory TestingAmerican Journal of Clinical Pathology · 2026
- Association Between Serum Magnesium and Calculated HOMA in a Turkish Clinical PopulationMedicina · 2026
- Predictors of Hypomagnesemia Among Hospitalized Patients: A Retrospective Study.The American journal of nursing · 2026
- Clinical Relevance of Magnesium Supplementation In Type 2 Diabetes Mellitus.Mayo Clinic proceedings · 2026
- Diagnostic performance of calculated serum osmolarity versus clinical impression for identifying dehydration in older hospitalized patients.BMC geriatrics · 2026