A-288 Extending accurate patient-based QC and QA to outpatients undergoing 7 day, 14 day, 21 day or 28 day repeat laboratory testing.
George Cembrowski, Jialin Qiu, Christopher McCudden
Key points
From the paper's conclusion- We compared the average between-week hourly total test variation (analytical + intrapatient biological + preanalytical) to the European Federation of Laboratory Medicine (EFLM) upper limits of normal subject biological variation (PMID: 34049424).
Abstract
Background While some referral laboratories may use patient moving averages to detect potentially significant analytical shifts, diurnal variation will reduce their signal-to-noise ratio. To eliminate the interference of diurnal variation in hospital patients, we developed and demonstrated the effectiveness of the moving average of 24-hour intrapatient deltas (PMID: 33993233). The objective of this study was to quantitate the total variations of common chemistry tests that were resampled on weekdays 7 days, 14 days and 28 days later, extending hourly from the same time of sampling to 24 hours later. Methods Retrospective anonymized Siemens Vista chemistry results (electrolytes, lipids, urea, uric acid, total protein, total bilirubin, and glucose) were obtained from Ottawa Hospital outpatients. Results outside their reference interval were excluded from analysis. For each of 13 chemistry analytes, we tabulated consecutive intrapatient paired results that were analyzed between 6am and 6pm on weekdays and separated between 7, 14 or 28 days. The separation time (hours) was converted into a modulus 24 time yielding 24 hourly intervals. For each hourly interval, we calculated the relative Dahlberg standard deviation of the paired intrapatient results which constitutes the sum of analytical, intra-patient biological and any preanalytical variation (PMID: 35137000). We compared the average between-week hourly total test variation (analytical + intrapatient biological + preanalytical) to the European Federation of Laboratory Medicine (EFLM) upper limits of normal subject biological variation (PMID: 34049424). Results A total of 240,284 outpatient chemistry results were obtained between March 2014 and November 2019; mean female and male ages were 56+20 (SD) and 61+18 years, respectively. The average intrapatient total variations (%), between 7 days+1 hr, 14 days+1 hr, and 28 days+1 hr, periods (including analytical and intrapatient biologic variation and any preanalytical variation) are compared to the parenthesized EFLM intrasubject biologic variation (%): sodium: 1.4(0.6), chloride: 1.7(1.4), potassium: 6.5(4.5), magnesium: 5.0(4.5), calcium: 2.6 (2.3), bicarbonate: 5.4(2.3), phosphate: 10.3(8.3), creatinine: 8.6(5.0), urea: 16.7(14.1), ALT: 20(17.3 ), AST: 23(27.2), albumin: 4.2(3.0), total protein: 3.3(2.8) and total bilirubin: 20.5(27.2). Conclusion Most of the total Ottawa intrapatient variations are very close to, but slightly higher than those derived from the EFLM healthy subjects studies. In busy referral laboratories, running Dahlberg or average of delta calculations of 7, 14, 21 and 28 day intrapatient paired results should provide tight and reliable limits for within patient variation thus enabling weekday outpatient-based QA and QC of many frequently reordered chemistry components. Extension of the period between consecutive tests to broader durations such as 35 days might introduce unwanted, complicated seasonal variation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-267 Laboratory Professional Literacy and Conscious Test Repetition Using the Same Sample in Emergency and Urgent Care Settings: A Multi-Hospital Study from the Federal District, BrazilClinical Chemistry · 2026
- Time-of-Day-Associated Variation in Serum CO2 Patient-Result Distribution and Its Impact on PBRTQC Performance.Diagnostics (Basel, Switzerland) · 2026
- Diurnal variation of islet autoantibody titers in established type 1 diabetes suggests restricted-time sampling improves aab measurement and detection.Scientific reports · 2026
- B-252 Prospective real-time implementation and clinical validation of patient-based real-time quality control using average of normals in a tertiary hospital laboratorClinical Chemistry · 2026
- A-316 A Repetition Index for Monitoring and Reducing Routine Inpatient Laboratory TestingClinical Chemistry · 2026
- 41 Reference Interval Evolution: Why Expanding to the 99th Percentile Matters in Modern Laboratory TestingAmerican Journal of Clinical Pathology · 2026