American Journal of Clinical Pathology

34 Development and Implementation of a Broad-spectrum Urine Drug Panel in a Clinical Toxicology Laboratory

Zhicheng Jin, Jill Wolken

Key points

From the paper's conclusion
  • In this study, we described the development and implementation of a revised urine drug panel that monitors 44 drugs and metabolites, including opioids, benzodiazepines, and stimulants.

Abstract

Background Many urine drug testing methods are available on the market, including immunoassays on automated chemistry analyzers, point-of-care drug screening kits, laboratory developed tests on LC-MS/MS and GC-MS platforms. Clinical laboratory directors need to choose the appropriate tests to meet their hospital’s needs. Our toxicology laboratory offers a drug test on GC-MS and a pain management panel on LC-MS/MS instrument. Broad-spectrum urine drug test should be sensitive to prescription drug, such as buprenorphine, while also screening for other illicit drugs and metabolites. In this study, we described the development and implementation of a revised urine drug panel that monitors 44 drugs and metabolites, including opioids, benzodiazepines, and stimulants. Emerging illicit substances, xylazine and ketamine were also included in the panel. Method The multiplex assay quantified 44 compounds with 13 stable isotope-labeled internal standards (Table 1). Reverse-phase chromatographic separation was performed using an Accucore phenyl-hexyl column (2.6 µm, 2.1 x 100 mm) on an Agilent 1260 HPLC. Mass spectrometers were equipped with electrospray ionization source and operated in dynamic MRM mode. The total run time was 8 min per injection. Method validation was carried out according to the CLSI-C62-ED2 guideline. This assay was validated on both API 4500 and Triple-Quad 6500 systems. Results The analyte measurable range (AMR) was 1 to 200 ng/mL for fentanyl and norfentanyl, and 25 to 1000 ng/mL for other drugs and metabolites. The within-day CVs were ≤ 12% and the between-day CVs were ≤ 16% for all analytes on both instruments. The method accuracy was evaluated by performing a split-sample comparison with a reference laboratory and testing 22 remnant CAP survey specimens (DMPM and UDS surveys). The assay sensitivity, carryover, matrix effect, and interference studies met the acceptance criteria. Results were reported semi-quantitatively and as low, medium, and high. Operational challenges such as turn-around time, secondary review, and billing will be discussed. Case studies of unexpected positive and negative results for patients prescribed with oxycodone, buprenorphine, and lorazepam will be presented. Conclusion We developed, validated, and implemented a fast, sensitive, and robust LC-MS/MS pain management panel that monitors 44 drugs and metabolites. This comprehensive drug panel offers primary care doctors a valuable tool for monitoring prescription drug compliance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers