B-403 Validation of a high-resolution mass spectrometry-based comprehensive drug test
Gillian Rexroad, Priscilla Yeung, Morgan Mann, John Ochoa, Kara Lynch
Key points
From the paper's conclusion- In this study, we transitioned our high-resolution mass spectrometry-based (HRMS) comprehensive drug test from a SCIEX TripleTOF®5600 to the SCIEX X500R QTOF.
Abstract
Background Liquid chromatography tandem mass spectrometry (LC-MS/MS) is a powerful tool for toxicology testing, providing critical information about substances causing overdoses and statistics on drug use within the patient community. In this study, we transitioned our high-resolution mass spectrometry-based (HRMS) comprehensive drug test from a SCIEX TripleTOF®5600 to the SCIEX X500R QTOF. In addition to validating the assay, we expanded our library of drugs with additional substances seen in our patient population, including illicit drugs such as fentanyl analogs and designer benzodiazepines. Methods Data was collected with high-resolution mass spectrometry (HRMS) on a SCIEX X500R QTOF using information dependent acquisition. The assay was validated for urine, serum, plasma, and whole blood samples. Scores were calculated for each compound based on mass error, retention time, isotope pattern, and library match; all data was manually reviewed for final calls. Limits of detection and matrix effects were quantified in urine and serum using 5-10 blank matrices into which mixes of drug standards were spiked. Over 90 (urine) and 50 (serum) patient comparisons were analyzed to assess equivalency of the instruments. Results A new spectral library was built on the X500R for over 220 compounds, including 18 compounds not part of the previously validated assay. Limits of detection were determined in the range of 5-5000 ng/mL and 1-1000 ng/mL in urine and serum, respectively. Carryover effects were assessed with spiking studies and determined to be negligible. Matrix effects showed ion suppression or enhancement depending on the compound without significantly affecting LODs. The comprehensive drug test was validated and implemented clinically. With the X500R we detect 704 of 787 (∼89%) compounds originally detected on the 5600; however, the X500R additionally detects 129 compounds not picked up by the 5600, yielding ∼6% improved sensitivity. Additionally, we detect at least one of the newly added compounds to our library in about one third of urine patient comparisons analyzed, with the most frequently observed compounds being 4-ANPP (fentanyl precursor) and beta-hydroxy fentanyl (fentanyl analog). Conclusion We present a framework for validation and implementation of a HRMS-based comprehensive drug test in the clinical lab, including assessment of limits of detection, matrix effects, carryover, and evaluation of the assay using patient samples. Expansion of our menu to reflect drug use trends in our patient population provides valuable clinical information and furthers our bio-surveillance efforts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of a Dried Blood Spot (DBS) Liquid Chromatography - High-Resolution Mass Spectrometry (LC-HRMS) workflow for simultaneous identification of emerging opioids.Forensic science international · 2026
- B-421 Validation of high-resolution mass spectrometry-based targeted drug screeningClinical Chemistry · 2026
- 34 Development and Implementation of a Broad-spectrum Urine Drug Panel in a Clinical Toxicology LaboratoryAmerican Journal of Clinical Pathology · 2026
- B-419 Rapid and Automated Magnetic Bead–Based Sample Preparation for Multi-Class Drugs of Abuse Analysis by LC–MS/MSClinical Chemistry · 2026
- Development and Validation of an Oral Fluid LC-MS/MS Method for Screening Emerging Synthetic Opioids Including Fentanyl Analogues, Nitazenes, and Xylazine.Journal of analytical toxicology · 2026
- A Validated Multi-Analyte Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Therapeutic Drug Monitoring and Targeted Toxicological Assessment of 54 Drugs and Metabolites in Human Serum.Journal of separation science · 2026