Gamma-ray response of a GAGG:Ce scintillator coupled to a 2 × 2 SiPM array
Zibo Qin, Zaihong Yang, Kaijie Zhou, Xiangyang Jiang, Zhongtao Shen, Qite Li, Jiawei Bian, Zeyu Du,
Key points
From the paper's conclusion- A relatively large 35 × 35 × 20 mm 3 GAGG:Ce scintillator coupled to a 2 × 2 silicon photomultiplier (SiPM) array was characterized for gamma-ray detection, including relative-gain calibration, nonlinear energy response, energy resolution, and timing resolution.
Abstract
A relatively large 35 × 35 × 20 mm 3 GAGG:Ce scintillator coupled to a 2 × 2 silicon photomultiplier (SiPM) array was characterized for gamma-ray detection, including relative-gain calibration, nonlinear energy response, energy resolution, and timing resolution. The SiPM-array response was well described by a saturation-inspired nonlinear calibration function. For the gain-calibrated individual-readout configuration, energy resolutions of 5.31(9)% at 1173.2 keV and 5.05(8)% at 1332.5 keV were obtained, while offline-simulated summed readout yielded comparable values. Coincidence measurements using 60 Co yielded single-detector timing resolutions of σ = 429(9) ps for individual readout and σ = 425(9) ps for hardware-summed readout. Sensitivity to low-energy gamma rays was also demonstrated by detecting the 59.5-keV line from 24 Am. These results provide a useful performance reference for compact gamma-ray detector designs based on relatively large GAGG:Ce crystals and SiPM-array readout.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Large-Volume GAGG(Ce) Detector Module for In-Beam $\gamma$-Ray SpectroscopyarXiv · 2026
- High-energy gamma-ray spectrometry with LYSO:Ce scintillators for fusion plasma experiments.The Review of scientific instruments · 2026
- Development of ultrafast and radiation-hard GAGG for the next-generation of High-Energy Physics calorimetersNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- A large neutron/gamma detector based on the EJ-276G plastic scintillator read out with multiple SiPM arraysNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2025
- Experimental characterization and Monte Carlo validation of a GAGG/SiPM gamma camera prototype for 111 Ag imagingJournal of Instrumentation · 2026
- Study on light output uniformity of the CEPC-GS-HCAL scintillator detector cellsJournal of Instrumentation · 2026