Journal of Instrumentation

Study on light output uniformity of the CEPC-GS-HCAL scintillator detector cells

Heng Zhao, Gao Tang, Sen Qian, Boxiang Yu, Xin Ling, Zhehao Hua, Dong Yang, Hua Cai,

Key points

From the paper's conclusion
  • Cosmic-ray MIPs spectroscopy measurements show that the detector unit combining high-density glass scintillator and NDL-SiPM achieves an average light output of more than 120 photoelectrons (P.E.), which is considered a reasonable performance level for a ten-year operational lifetime.

Abstract

As a core component of the CEPC Higgs factory, a Glass Scintillator hadron calorimeter (GS-HCAL) is being developed to replace the plastic scintillator design (PS-HCAL), employing stainless steel as the absorber and glass scintillator (GS) as the active medium. The detector unit consists of glass scintillator coupled with silicon photomultipliers (SiPMs). Based on this, a novel glass scintillator cell structure with dimensions of 40 mm× 40 mm× 10 mm has been developed. Although the CEPC Reference Detector Technical Design Report has simulated the optical attenuation length, cosmic-ray minimum ionizing particles (MIPs) response light output, and their impact on energy resolution for the GS-HCAL, systematic experimental data on the intra-cell light output uniformity are still lacking. This missing information is critical because intra-cell non-uniformity directly affects signal stability and overall energy resolution, yet no experimental characterization has been reported for this cell size. In this work, we experimentally characterize this uniformity to fill the gap, providing essential input for refining GS-HCAL simulations and optimizing the detector cell design. According to experimental data, the non-uniformity of light output for this structure is controlled within 43%. In this paper, the performance of the CEPC-GS-HCAL detector unit is studied using SiPMs (EQR20-11-3030D-S) manufactured by the Novel Device Laboratory (NDL). Cosmic-ray MIPs spectroscopy measurements show that the detector unit combining high-density glass scintillator and NDL-SiPM achieves an average light output of more than 120 photoelectrons (P.E.), which is considered a reasonable performance level for a ten-year operational lifetime.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Study on light output uniformity of the CEPC-GS-HCAL scintillator detector cells — Science Skim