Experimental characterization and Monte Carlo validation of a GAGG/SiPM gamma camera prototype for 111 Ag imaging
E. Borciani, D. Serafini, G. Baldazzi, C. Sbarra, M. Negrini, A. Margotti, S. Spadano, G. Giannaccini,
Key points
From the paper's conclusion- These results demonstrate the feasibility of a prototype modular gamma camera, built using off-the-shelf components, for high-energy imaging of 111 Ag and provide an experimental platform for future optimization of collimation and reconstruction techniques.
Abstract
A compact gamma camera prototype has been developed within the Isotope Separation On-Line production of radioPHARMaceutical (ISOLPHARM)–Advanced Dosimetry Methods and In-vitro Radiobiology of 111 Ag Labeled radiopharmaceuticals (ADMIRAL) project to enable laboratory studies and small animal imaging applications of the theranostic radionuclide 111 Ag, whose main gamma emission at 342 keV is above the energy range of conventional clinical systems, optimized for 99m Tc. The detector consists of a square-holes tungsten collimator facing a 23×23 pixelated GAGG(Ce) scintillator array optically coupled to an 8×8 Hamamatsu SiPM matrix and read out by a CAEN FERS (A5202) board, based on CITIROC 1A ASICs. A Geant4-based Monte Carlo application, including optical photon transport and an electronics-noise model, was developed and validated through laboratory measurements. The prototype was characterized using a 133 Ba point-source-like and 111 Ag extended sources. For 111 Ag, an energy resolution of Δ E / E ≈ 24 % was observed at the 342 keV photopeak. Spatial resolution was assessed to be approximately 3 mm, in agreement with expectations from the Monte Carlo simulation. The efficiency of the camera on the γ-spectrum of 111 Ag was measured to be 2.1 × 10 -4 . Finally, a preliminary mouse phantom study featuring multiple active regions confirmed the capability to qualitatively localize multiple activity regions. These results demonstrate the feasibility of a prototype modular gamma camera, built using off-the-shelf components, for high-energy imaging of 111 Ag and provide an experimental platform for future optimization of collimation and reconstruction techniques.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Monte Carlo simulation of the ISOLPHARM gamma camera for Ag-111 imagingJournal of Instrumentation · 2026
- Gamma-ray response of a GAGG:Ce scintillator coupled to a 2 × 2 SiPM arrayJournal of Instrumentation · 2026
- A Large-Volume GAGG(Ce) Detector Module for In-Beam $\gamma$-Ray SpectroscopyarXiv · 2026
- Omnidirectional Radiation Detector with Perpendicular Dual Silicon Photomultiplier Readout - Directional Sensitivity and Machine Learning Source PositioningarXiv · 2026
- Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study.Materials (Basel, Switzerland) · 2026
- Design and performance evaluation of a GAGG:Ce long-bar Compton camera with dual-ended DOI readout using Geant4 simulations.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026