GEANT4-based comparative study of detector response in reduced and fully instrumented silicon-tungsten sampling calorimeter
Abhijeet Laha, Subikash Choudhury, Sanjib Muhuri, Mitali Mondal
Key points
From the paper's conclusion- The results demonstrate that the reduced prototype successfully reproduces the main characteristics of electromagnetic shower development observed in the fully instrumented detector, establishing its usefulness for detector characterization and test-beam studies when the construction of a complete prototype is limited by available resources.
Abstract
A GEANT4-based simulation study of a silicon-tungsten (Si-W) sampling calorimeter is presented to investigate electromagnetic shower development and detector response in the energy range of 1–120 GeV. Two detector configurations are considered: a reduced sequential-sampling prototype (Configuration-I), where a single silicon detector layer is placed downstream of progressively increasing tungsten absorber depths to sample the longitudinal shower evolution, and a fully instrumented sampling calorimeter (Configuration-II) consisting of twenty silicon layers interleaved with tungsten absorbers. The detector response is studied in terms of longitudinal shower development, shower maximum position, energy deposition, detector linearity, and calorimetric performance. Configuration-II provides simultaneous longitudinal sampling and allows event-by-event reconstruction of the deposited energy, yielding the expected linear response and energy resolution. Configuration-I reproduces the average longitudinal shower profiles and exhibits a strong linear correlation with the integrated shower response of Configuration-II. Although the absence of event-by-event multi-layer sampling prevents a direct determination of calorimetric energy resolution in Configuration-I, the observed correlation between two configurations is used to relate the response of the reduced prototype to that of the fully instrumented calorimeter and to estimate the corresponding calorimetric performance. The results demonstrate that the reduced prototype successfully reproduces the main characteristics of electromagnetic shower development observed in the fully instrumented detector, establishing its usefulness for detector characterization and test-beam studies when the construction of a complete prototype is limited by available resources.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comprehensive study of timing resolution in plastic scintillator detectors with wavelength-shifting fiber and silicon photomultiplier readoutJournal of Instrumentation · 2026
- HybridMC: a fast detailed simulation framework for optical calorimeter technologies at the LHCb ECAL Upgrade IIarXiv · 2026
- Study on light output uniformity of the CEPC-GS-HCAL scintillator detector cellsJournal of Instrumentation · 2026
- Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study.Materials (Basel, Switzerland) · 2026
- Development of a highly granular silicon-tungsten electromagnetic calorimeter prototype for the LUXE experimentJournal of Instrumentation · 2026
- Time-over-threshold versus pulse-height energy reconstruction in a PbWO$_4$ calorimeter read out by SiPMsarXiv · 2026