Comprehensive study of timing resolution in plastic scintillator detectors with wavelength-shifting fiber and silicon photomultiplier readout
H. Che, G. Yang
Key points
From the paper's conclusion- We present a comprehensive study of the timing resolution achievable in plastic scintillator detectors read out through wavelength-shifting (WLS) fibers coupled to silicon photomultipliers (SiPMs), combining a semi-analytical framework, toy Monte Carlo validation, and full Geant4 optical photon simulation.
Abstract
We present a comprehensive study of the timing resolution achievable in plastic scintillator detectors read out through wavelength-shifting (WLS) fibers coupled to silicon photomultipliers (SiPMs), combining a semi-analytical framework, toy Monte Carlo validation, and full Geant4 optical photon simulation. The analytical model traces the complete photon detection chain: scintillation emission, WLS fiber re-emission, optical transit time dispersion, SiPM single-photon time resolution, and electronics quantization. It expresses the timing resolution σ t as a function of the detected photoelectron yield N pe , scintillator decay constants ( τ r , τ d ), WLS re-emission time ( τ WLS ), fiber numerical aperture, detector geometry, and readout electronics parameters. The analytical predictions are validated at two levels. First, toy Monte Carlo simulations (2 × 10 5 events per parameter point across 80 grid points spanning 8 fiber types and N pe from 5 to 200) achieve analytical-to-MC agreement of 1.0000 ± 0.0018. Second, full Geant4 optical photon simulations track the entire scintillation, wavelength-shifting, and fiber transport chain in realistic detector geometries, confirming the analytical timing predictions to within 10–20% for N pe ≳ 10 and providing first-principles photoelectron yield calibration. A comprehensive parameter scan covering 7 scintillator materials, 8 WLS fiber types, 5 SiPM models, 5 electronics configurations, 3 readout topologies, and 3 boundary conditions produces quantitative design maps and lookup tables for detector optimization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- SiPM optical readout of a PICOSEC Micromegas precise timing detectorarXiv · 2026
- GEANT4-based comparative study of detector response in reduced and fully instrumented silicon-tungsten sampling calorimeterJournal of Instrumentation · 2026
- HybridMC: a fast detailed simulation framework for optical calorimeter technologies at the LHCb ECAL Upgrade IIarXiv · 2026
- Machine learning-based experimental access to photon-by-photon arrival times in scintillation detectors.Physics in medicine and biology · 2026
- Optical Characterization Measurements of Commercial Polyvinyltoluene Scintillators for Accurate Geant4 Detector ModelingarXiv · 2026
- High-performance planar TOF-PET imagerJournal of Instrumentation · 2026