Development of a highly granular silicon-tungsten electromagnetic calorimeter prototype for the LUXE experiment
Veta Ghenescu,
Key points
From the paper's conclusion- The current status of the prototype development and comparisons with simulation studies are also discussed.
Abstract
Highly compact and highly granular electromagnetic calorimeters are required for precision luminosity measurements at future e + e - colliders. Such detectors are also essential for determining the positron multiplicity and energy spectra in the LUXE experiment [1], which investigates strong-field QED through laser-electron interactions. In a luminometer, where Bhabha scattering serves as the gauge process, a compact sampling calorimeter with a small Molière radius enables a precise definition of the fiducial volume, improves the separation of electromagnetic showers from low-energy background, and reduces the required detector space. The proposed calorimeter design consists of alternating tungsten absorber plates and thin silicon detector layers. A similar design is needed to cover a large range of positron multiplicities the LUXE experiment. A partially instrumented multi-plane prototype with up to 11 silicon detector layers was tested in 1–6 GeV electron beams at the DESY II synchrotron. Each detector plane consists of a silicon pad sensor mounted on flexible Kapton circuits and supported by a lightweight carbon-fiber structure, enabling highly compact instrumentation with sub-millimeter thickness. The detector planes were installed in 1.2 mm gaps between tungsten absorber plates corresponding to one radiation length each. Each plane consists of a 90 × 90 mm 2 silicon pad sensor segmented into a 16 × 16 matrix. The readout electronics, positioned outside of the stack, employ FLAME [2] ASICs integrating analogue front-end electronics and 10-bit ADCs. High-statistics data were collected to perform precise detector alignment and to investigate the longitudinal and transverse development of electromagnetic showers. Preliminary results on energy, position, and angular resolution, as well as measurements of the Molière radius and shower development, are presented. The current status of the prototype development and comparisons with simulation studies are also discussed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Test of a partly instrumented highly compact and granular electromagnetic calorimeter in an electron beam of 1–6 GeVThe European Physical Journal Plus · 2026
- A high-flux electron detection system to measure non-linear Compton scattering at LUXEJournal of Instrumentation · 2026
- GEANT4-based comparative study of detector response in reduced and fully instrumented silicon-tungsten sampling calorimeterJournal of Instrumentation · 2026
- High-sensitivity monolithic photonic electric-field probe for 40-110 GHz operation.Optics letters · 2026
- Design and synthetic diagnostic of a vertical multi-energy soft x-ray camera for the WEST tokamak.The Review of scientific instruments · 2026
- Evidence for MeV Radiation from a Large-Amplitude Crystalline UndulatorarXiv · 2026