Calibration of X-ray multimeters for half-value layer: measurement methods and uncertainty evaluation
Aino Tietäväinen, Paula Toroi, Bartel Joris Jansen, Katy Klauenberg, Siarhei Saroka, Jaroslav Šolc, Gerd Wuebbeler, Milos Zivanovic
Key points
From the paper's conclusion- This work presents a detailed approach for determining the first HVL and calibrating XMMs for RQR 2, RQR 5, and RQR 10 standard radiation qualities for radiography as defined in IEC 61267.
Abstract
The first half-value layer (HVL), defined as the thickness of material required to reduce the X-ray beam intensity (air kerma) to 50%, is a key radiation quality specifier. Although HVL has been measured for decades using ionization chambers and aluminum filters, the detailed measurement procedures and associated uncertainties remain insufficiently established. With the growing use of X-ray multimeters (XMMs) capable of measuring HVL directly from the X-ray beam, reliable calibration and uncertainty evaluation are needed. This work presents a detailed approach for determining the first HVL and calibrating XMMs for RQR 2, RQR 5, and RQR 10 standard radiation qualities for radiography as defined in IEC 61267. The uncertainty budget is structured into three steps: measured HVL, reference HVL, and HVL calibration coefficient, emphasizing the effects of ionization chamber energy dependence and field size. The reference HVLs for RQR 2, RQR 5, and RQR 10 were 1.417 mm Al, 2.570 mm Al, and 6.510 mm Al, respectively, with expanded uncertainties (k = 2) of 1.0%, 1.1%, and 1.7%. The corresponding HVL calibration coefficients had uncertainties of 1.4%, 1.3%, and 1.8%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration of X-ray multimeters for radiography.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Experimental Comparison of Half-Value Layer Measurements Using a Solid-State X-ray Meter and an Ionization Chamber in General Radiography.Cureus · 2026
- Experimental and Monte Carlo validation of DIN 6809-4:2020 kilovoltage X-ray beam qualities for secondary standard dosimetry applications.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Impact of a common user-derived electrometer calibration coefficient on absorbed dose-to-water determination: a multicenter uncertainty studyJournal of Radioanalytical and Nuclear Chemistry · 2026
- Empirical and semi-empirical methods to determine the kV exponent (n value) for diagnostic X-ray machines.Radiation protection dosimetry · 2026
- Performance of air kerma - area product meters based on long-term calibration data.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026