Accommodative balance in clinical versus metric-optimised prescriptions for adults with Down syndrome.
Lauren V Schneider, Jason D Marsack, Heather A Anderson
The Ohio State University College of Optometry, Columbus, OH, USA. · Department of Vision Science, University of Houston College of Optometry, Houston, TX, USA.
Key points
From the paper's conclusion- Inter-eye differences in VA and accommodative lag were not clinically meaningfully different for any experimental refraction, indicating each refraction was similarly balanced.
Abstract
CLINICAL RELEVANCE: Wavefront-guided objective refractions can be a useful tool for optimising refractions for patients who may have difficulties with subjective refraction. Since these objective refractions are monocularly derived, information about the binocular balance to accommodation is important when clinicians consider prescribing with this method. BACKGROUND: Wavefront-guided objective refractions have been investigated in patient populations that have highly aberrated optics and/or difficulty with subjective input, such as people with Down syndrome (DS). However, these objective refractions are determined for each eye individually, unlike a subjective refraction that considers both eyes. This study aimed to compare the interocular balance between objective and subjective prescriptions for adults with DS. METHODS: Thirty adults with DS (age 29 ± 10 yrs) were enrolled in a trial to compare performance of clinical refraction versus refractions optimising visual Strehl ratio (VSX) and pupil fraction tessellated (PFSt) metrics from analysis of dilated wavefront measures (21 participants used for analysis). Visual acuity (VA) via a logMAR-style chart and accommodative lag via MEM retinoscopy were measured. Absolute differences and Pearson correlations for VA and lag were calculated between the eyes of each participant. Repeated measures ANOVA was used to compare inter-eye differences by refraction type. RESULTS: Mean right eye VA ranged from 0.32 ± 0.17 logMAR to 0.38 ± 0.18 logMAR (p = 0.06) and mean inter-eye difference ranged from 0.09 ± 0.06 logMAR to 0.09 ± 0.10 logMAR (p = 0.98) across correction types. Mean right eye lag ranged from 1.31 ± 0.52D to 1.38 ± 0.68D (p = 0.89) and mean inter-eye difference ranged from 0.15 ± 0.29D to 0.31 ± 0.37D (p = 0.09) across correction types. Left and right eye VA and lag were positively correlated. CONCLUSIONS: Inter-eye differences in VA and accommodative lag were not clinically meaningfully different for any experimental refraction, indicating each refraction was similarly balanced.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Wavefront-optimised Refraction Determined Pre- and Post-cycloplegia in Individuals with Down Syndrome.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Comparison of refractive error measurements obtained with a pyramid wavefront sensor topo-aberrometer and an auto kerato-refractometer against subjective refraction.Clinical & experimental optometry · 2026
- Comparison of Refraction Obtained with the Myopia Master and Subjective Manifest Refraction in Pediatric Orthokeratology.Diagnostics (Basel, Switzerland) · 2026
- A Digital Twin-Inspired Patient-Specific Eye-Lens Simulation Framework for Pediatric Postcycloplegic Spectacle Prescription: A Prospective Agreement Study.Translational vision science & technology · 2026
- Visual Performance of a Novel Intraocular Lens With Higher-Order Aspheric Design Optimized for Intermediate Vision.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- The Visual Impact of Uncorrected Astigmatism in Eyes Fitted with Dual Focus Myopia Control Lenses.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026