A Digital Twin-Inspired Patient-Specific Eye-Lens Simulation Framework for Pediatric Postcycloplegic Spectacle Prescription: A Prospective Agreement Study.
Hong Chang, Yi Zhen, Yan Huang, Jie Gao
Beijing He Eye Specialist Hospital, Beijing, China. · National Engineering Research Center for Ophthalmology, Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Engineering Research Center of the Ministry of Education for Ophthalmic Diagnosis and Treatment Equipment and Materials, Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- The digital twin-inspired patient-specific eye-lens simulation framework generated pediatric postcycloplegic prescription estimates that agreed more closely with subjective refraction than traditional autorefraction, particularly for SE. These findings support its feasibility as an upstream decision support component, although real-world spectacle wear feedback and longitudinal model updating require further study.
Abstract
PURPOSE: To evaluate the agreement of a digital twin-inspired patient-specific eye-lens simulation framework and reference-standard subjective refraction for pediatric postcycloplegic spectacle prescription. METHODS: In this prospective randomized testing sequence agreement study, 183 right eyes from 183 children (mean age, 9.9 ± 2.0 years) underwent traditional autorefraction, artificial intelligence (AI) wavefront refraction, and masked subjective refraction. The framework used microelectromechanical systems (MEMS) Shack-Hartmann wavefront data, image quality gating, virtual trial-lens simulation, and perturbation-aware optimization to generate an AI-based prescription estimate. Agreement was assessed for spherical equivalent (SE), Jackson cross-cylinder component at axis 0° (J0), and Jackson cross-cylinder component at axis 45° (J45). RESULTS: Traditional autorefraction differed significantly from subjective refraction in SE, J0, and J45: 0.21 ± 0.52 diopters (D) for SE (P < 0.001), -0.04 ± 0.21 D for J0 (P = 0.006), and 0.02 ± 0.13 D for J45 (P = 0.037). AI wavefront refraction showed smaller mean differences without statistically significant differences: 0.04 ± 0.35 D for SE (P = 0.153), -0.01 ± 0.19 D for J0 (P = 0.681), and 0.00 ± 0.15 D for J45 (P = 0.725). For SE, AI wavefront refraction showed narrower 95% limits of agreement than traditional autorefraction (-0.67 to 0.74 D vs. -0.81 to 1.22 D) and higher proportions within ≤0.25 D and ≤0.50 D (66.1% vs. 54.6%; 91.3% vs. 86.9%). CONCLUSIONS: The digital twin-inspired patient-specific eye-lens simulation framework generated pediatric postcycloplegic prescription estimates that agreed more closely with subjective refraction than traditional autorefraction, particularly for SE. These findings support its feasibility as an upstream decision support component, although real-world spectacle wear feedback and longitudinal model updating require further study. TRANSLATIONAL RELEVANCE: This study provides prospective clinical validation for an upstream component of a future human-in-the-loop ophthalmic digital twin for spectacle prescription by translating patient-specific wavefront data into virtual trial-lens simulation and AI-assisted refraction decision support.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysisFrontiers in Digital Health · 2026
- Accuracy of intraocular lens power calculation in pediatric aphakia with the Artisan iris-claw lens.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Comparison of Refraction Obtained with the Myopia Master and Subjective Manifest Refraction in Pediatric Orthokeratology.Diagnostics (Basel, Switzerland) · 2026
- A personalized simulation framework for optimizing orthokeratology lens parameters based on 3D corneal modeling and biomechanical analysis.Frontiers in bioengineering and biotechnology · 2026
- Machine Learning-Based Prediction of Cycloplegic Refraction Using the Eyerobo Vision Screener: Design-A Cross-Sectional Comparative Device Study.Ophthalmology and therapy · 2026
- The Comparative Effectiveness of Four Myopia-Control Spectacle Lenses: A Real-World AIPW Cohort Study.Healthcare (Basel, Switzerland) · 2026