Quantifying Stress Shielding in Dental Implants: A Comparative Finite Element Study of Titanium, CFR-PEEK, and Ceramic Materials
Mario Ceddia, Tea Romasco, Natalia Di Pietro, Alessandro Cipollina, Adriano Piattelli, Luciano Lamberti, Bartolomeo Trentadue
Polytechnic University of Bari · University of Chieti-Pescara
Key points
From the paper's conclusion- We modelled the bone as linearly isotropic in the transverse direction and the implants as linearly isotropic with a fully bonded interface.
Abstract
Background: Stress shielding, which occurs when there is a mismatch between the stiffness of the implant and the bone, can alter load transfer and drive peri-implant bone remodeling, particularly in low-density bone. Methods: We compared the biomechanical responses of one-piece implants made of Ti-6Al-4V, Y-TZP, and CFR-PEEK. We modelled the bone as linearly isotropic in the transverse direction and the implants as linearly isotropic with a fully bonded interface. A static load of 200 N was applied at an inclination of 30° buccal-to-lingual, with the transverse bone bottom faces fully constrained. Results: The peak cortical von Mises stress was highest for Y-TZP (87 MPa), followed by Ti-6Al-4V (57 MPa) and CFR-PEEK (approximately 37 MPa). Peak cortical von Mises strain showed the same relative order of magnitude: 3450 µε, 3103 µε, and 1523 µε, respectively. The stress-shielding factor (SSF) revealed that shielding was present in the mid-apical regions. Y-TZP exhibited the greatest shielding (SSF: 0.844–0.877), followed by Ti-6Al-4V (SSF: 0.380–0.568) and CFR-PEEK (SSF: 0.375–0.437). No crestal shielding was observed (SSF < 0). Conclusions: Overall, implants with higher stiffness increased crestal stress concentration and deepened peri-implant shielding. Meanwhile, CFR-PEEK improved load sharing and produced a more homogeneous mechanical stimulus in low-density bone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of the postoperative mechanical properties of PEEK bone plates in a distal femoral fracture model.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element AnalysisEuropean Journal of General Dentistry · 2026
- Effect of distal cantilever and anterior implant diameter on framework and cortical bone stress in a PEEK-based All-on-Four mandibular prosthesisFrontiers in Dental Medicine · 2026
- Overcoming the Biomechanical Limitations of Titanium-Zirconia Dental Implants: Rationale for a Novel Ti-PEEK-Zr Tri-Layered Concept.Journal of functional biomaterials · 2026
- Zirconia abutments and reduced crown-to-implant ratios: Insights into stress distribution.Brazilian oral research · 2026
- Design and comparison of custom cranial prostheses made of titanium and polyether ether ketone using the finite element methodJournal of Materials Science: Materials in Medicine · 2026