Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fractures
Patrick Riegner, Christian Spiegel, F. Peter Kohler, Heike Kielstein, Ivan Zderic, Boyko Gueorguiev-Rüegg, Mark Lenz, Wolfram Weschenfelder
Jena University Hospital · University Hospital in Halle
Key points
From the paper's conclusion- In this unstable intra-articular fracture model with radiodorsal metaphyseal comminution, six distal screws reduced post-cyclic axial deformation and radial fragment-shaft micromotion compared with four screws. The clinical relevance of these findings remains to be determined.
Abstract
INTRODUCTION: This biomechanical study compared the fracture stability of a palmar plate combined with a headless compression screw (HCS) with that of a radiopalmar double-plate construct for AO/OTA 23-C2.1 distal radius fractures with metaphyseal defect zones. MATERIALS AND METHODS: Eleven matched pairs of cryopreserved human radii were prepared with standardized AO/OTA 23-C2.1 fractures. Left radii (n = 11) were fixed with a palmar plate plus HCS, while right radii (n = 11) received a radiopalmar double-plate construct. Construct stiffness and axial displacement were assessed using a universal testing machine. Interfragmentary range of motion (ROM) and rotation (ROT) were quantified using an optical three-dimensional motion-tracking system. Measurements were obtained before and after 5000 cycles of dynamic axial loading at 150 N. Two specimen pairs were excluded due to early failure or incomplete data acquisition. RESULTS: Both constructs demonstrated comparable stiffness and axial displacement, with no implant loosening or hardware failure observed. Interfragmentary ROM did not differ significantly between groups. However, the plate–HCS construct showed greater variability in rotational parameters. Initial radial-shaft rotation was significantly greater in the plate–HCS group (1.14° vs. 0.51°, p = 0.02). After cyclic loading, ulnar-shaft rotation increased significantly in the plate–HCS group (0.97° to 1.16°, p = 0.02) but not in the double-plate group. CONCLUSION: In this cadaveric model, fixation with a palmar plate combined with an HCS provided comparable axial stability but demonstrated greater variability and less consistent rotational control compared with radiopalmar double plating. Clinical studies are required to determine whether this less invasive construct achieves equivalent outcomes in vivo.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical comparison of radiopalmar double plating with conventional palmar plating in comminuted distal radius fracturesArchives of Orthopaedic and Trauma Surgery · 2026
- Does additional radial column plating improve clinical and radiological outcomes in distal radius fractures with radial styloid involvement or severe comminution?: A retrospective cohort study with 2-year follow-up.Medicine · 2026
- Dual Plating and Dorsal Bridge Plating for Comminuted Distal Radius Fractures: A Systematic Review.Journal of clinical medicine · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Intraarticular calcaneal fractures: biomechanical analysis of two fixation constructs.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- A biomechanical comparison of closed-reduction osteosynthesis techniques for fractures of the ulnar styloid.Journal of orthopaedic surgery and research · 2026