ITM Web of Conferences

Low-Power Threshold-Based Absolute-Value Detector for Event-Driven Biomedical Sensor Nodes

Jintao Gou

Key points

From the paper's conclusion
  • Therefore, a simple event monitor can be placed before a complex processor so that costly computation is activated only when potentially relevant data are detected.

Abstract

Wearable biomedical devices must monitor physiological signals continuously under a limited energy budget. Therefore, a simple event monitor can be placed before a complex processor so that costly computation is activated only when potentially relevant data are detected. This paper presents a four-bit threshold-based absolute-value detector for this purpose. The circuit accepts a signed two’s-complement input A [3:0], computes its three-bit magnitude, and sets Y = 1 when |A| > T [2:0]. The design uses static-CMOS and transmission-gate subcircuits and was verified at the transistor level in LTSpice. At V DD = 1.0 V, the critical-path delay was 68.83 ps and the total test energy was 43,774.42 fJ. Supply-voltage scaling was then applied under the constraint D ≤ 1.4 D min. At V DD = 0.8575 V, the delay was 96.26 ps and the energy was 24,153.39 fJ, corresponding to a reduction of 44.82%. Because the initial output buffer was already small and the load was fixed at 32 C g1, buffer resizing produced only a minor change in energy.

Read the paper