Nano-Power OTA-Based Low-Pass Filter for Ultra-Low-Energy Biomedical Signal Processing
Tomasz Kulej, Montree Kumngern, Fabian Khateb
Częstochowa University of Technology · King Mongkut's Institute of Technology Ladkrabang
Key points
From the paper's conclusion- ECG signal simulations validate the circuit's effectiveness in suppressing high-frequency artifacts while preserving morphological integrity, providing a proof-of-concept for ultra-low-power wearable healthcare architectures.
Abstract
This paper presents a nanowatt-scale operational transconductance amplifier (OTA) and an electronically tunable third-order low-pass filter (LPF) designed for energy-constrained biomedical signal conditioning. The circuits are implemented in a 65 nm CMOS process and verified through comprehensive schematic-level simulations. Biased in the deep subthreshold region at 1 nA, the OTA achieves a 50 dB low-frequency gain, a 225 Hz unity-gain bandwidth at 10 pF load capacitance and an input-referred noise floor of 1.55 μV/√Hz, with a total power consumption of only 1.75 nW. The integrated third-order LPF provides a wide tuning range (37-668 Hz) via bias current modulation, exhibiting excellent linearity with a THD of 0.059% and a 65.3 dB dynamic range. Monte Carlo and PVT corner analyses demonstrate the design's theoretical robustness against process variations and environmental fluctuations. ECG signal simulations validate the circuit's effectiveness in suppressing high-frequency artifacts while preserving morphological integrity, providing a proof-of-concept for ultra-low-power wearable healthcare architectures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A 0.5 V 1.35 nW Fourth-Order DTMOS-Based Flipped Voltage Follower Low-Pass Filter with 70 dB Dynamic Range for ECG Signal AcquisitionTechnologies · 2026
- Circuit Innovations for Wearable Biomedical Monitoring: CMOS Analog Front-Ends and Data Converter ArchitecturesElectronics · 2026
- Evaluating Energy-Efficient Absolute-Value Detectors for Biomedical Signal ProcessingITM Web of Conferences · 2026
- 0.5-V Nano-Power Versatile First-Order Filter Using a Single DDTATechnologies · 2026
- Low-Power Threshold-Based Absolute-Value Detector for Event-Driven Biomedical Sensor NodesITM Web of Conferences · 2026
- An Ultra-Lightweight Event-Driven Neuromorphic Filter on FPGA with Approximate Robust Scaling for Cross-Modality Respiratory Monitoring.IEEE transactions on biomedical circuits and systems · 2026