Design and LTspice Simulation of 3-bit Two’s Complement Absolute Value CMOS Circuit for Wearable Sensors
Jun Tang
Key points
From the paper's conclusion- To cut extra power loss introduced by software threshold judgment, this paper designs a full combinational CMOS hardware circuit dedicated to calculating the absolute value of 3-bit two’s complement signals and comparing the result with preset threshold values.
Abstract
Wearable sensing devices commonly rely on microcontrollers to judge signal thresholds, which brings continuous power consumption and shortens battery life. To cut extra power loss introduced by software threshold judgment, this paper designs a full combinational CMOS hardware circuit dedicated to calculating the absolute value of 3-bit two’s complement signals and comparing the result with preset threshold values. The whole circuit adopts an unclocked architecture and is divided into three independent functional modules to avoid timing overhead and clock switching power consumption. Under a supply voltage of 1 V, transistor- level functional verification is completed with LTspice simulation, covering all valid input values of 3-bit two’s complement ranging from −4 to +3. Based on transient simulation waveforms, this paper tests the circuit’s critical transmission delay and average dynamic switching power. A joint optimization scheme combining transistor width adjustment and supply voltage tuning is proposed; within an acceptable range of delay increase, the overall circuit energy consumption can be significantly reduced. This lightweight all-hardware signal processing structure provides a low-power implementation scheme for front-end signal acquisition circuits of wearable sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gate-Level Design and Delay-Energy Evaluation of a 4-bit Absolute-Value Threshold Detector for Low-Power Biosignal Event DetectionITM Web of Conferences · 2026
- Low-Power Threshold-Based Absolute-Value Detector for Event-Driven Biomedical Sensor NodesITM Web of Conferences · 2026
- Evaluating Energy-Efficient Absolute-Value Detectors for Biomedical Signal ProcessingITM Web of Conferences · 2026
- A Fully Tunable Ultra-Low Power Current-Mode Memory Cell in Standard CMOS TechnologyEngineering Research Express · 2026
- CMOS rail-to-rail voltage-to-current converter circuit intended for low-voltage IC applicationsJournal of Electrical Engineering · 2026
- Circuit Innovations for Wearable Biomedical Monitoring: CMOS Analog Front-Ends and Data Converter ArchitecturesElectronics · 2026