Circuit Innovations for Wearable Biomedical Monitoring: CMOS Analog Front-Ends and Data Converter Architectures
Soumaya Sakouhi, Michele Dei
Key points
From the paper's conclusion- The resulting perspective highlights the transition from isolated block optimization toward circuit and architectural co-design for energy-efficient, robust wearable biomedical interfaces.
Abstract
Wearable biomedical monitoring systems increasingly demand CMOS interfaces capable of operating under stringent energy, voltage, and environmental constraints while maintaining a reliable acquisition of weak physiological signals. In this context, analog front-ends (AFEs) and data converters have evolved toward increasingly co-designed architectures that jointly address power consumption, signal fidelity, electrode-interface constraints, and robustness to real-world perturbations. This review examines recent circuit innovations in CMOS AFEs and AFE–ADC interfaces for wearable biomedical monitoring with emphasis on the circuit-level mechanisms used to improve power efficiency, noise performance, dynamic-range management, interface robustness, and tolerance to variability and artifacts. The review first establishes the physical and circuit-level constraints governing low-power biomedical acquisition and then organizes standalone AFE techniques according to three complementary design objectives: power, precision, and robustness. Particular attention is given to architectures that integrate or redistribute conventional AFE functions within the data-conversion path, including functional absorption, analog-resource reuse, and signal-domain transformation. Representative implementations from approximately the last five years are compared using reported circuit and system metrics to identify the trade-offs associated with these architectural choices. The resulting perspective highlights the transition from isolated block optimization toward circuit and architectural co-design for energy-efficient, robust wearable biomedical interfaces.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating Energy-Efficient Absolute-Value Detectors for Biomedical Signal ProcessingITM Web of Conferences · 2026
- Towards bioelectric signal-enabled human healthcare monitoring: state-of-the-art, design strategies, challenge, and futurenpj Biomedical Innovations. · 2026
- Nano-Power OTA-Based Low-Pass Filter for Ultra-Low-Energy Biomedical Signal ProcessingSensors · 2026
- Research on Multi-Dimensional Bionic Design of Flexible ECG Electrodes for Wearable Monitoring.Sensors (Basel, Switzerland) · 2026
- Vortex Convolver: A Biosignal Processor Based on Floating-Gate Spatial Computing.ACS nano · 2026
- A 0.5 V 1.35 nW Fourth-Order DTMOS-Based Flipped Voltage Follower Low-Pass Filter with 70 dB Dynamic Range for ECG Signal AcquisitionTechnologies · 2026