Soft matter

Separation-sensing Etalon@lateral flow assays for selective glucose sensing.

Georgia Kontaxi, Michael J Serpe, Hanieh Bazyar

Catalysis, Separation and Electrochemical Engineering, Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Van der Maasweg 9, 2629 HZ Delft, the Netherlands. h.bazyar@tudelft.nl. · Department of Chemistry, University of Alberta, Edmonton, Canada.

Key points

From the paper's conclusion
  • Here, we report a separation-sensing Etalon@lateral flow assay (Etalon@LFA) that integrates Nafion-functionalized regenerated cellulose (RC) membranes for simultaneous plasma separation and selective glucose detection via optical sensing.

Abstract

Point-of-care (POC) glucose monitoring requires simple, selective, and low-cost sensing platform capable of operating directly on minimally processed biological samples. Here, we report a separation-sensing Etalon@lateral flow assay (Etalon@LFA) that integrates Nafion-functionalized regenerated cellulose (RC) membranes for simultaneous plasma separation and selective glucose detection via optical sensing. The device is constructed by spray-coating RC membranes with Nafion to form a charge-selective separation layer, followed by the sensing element, a thermoresponsive poly(N-isopropylacrylamide) (pNIPAm) microgel-based etalon structure on RC membranes. Post-processing pNIPAm microgels with 3-aminophenylboronic acid (APBA) renders them responsive to glucose through reversible diol-boronate complexation. A single drop of blood-analogue sample, prepared via dispersion of polydimethylsiloxane (PDMS) particles in 4% sodium dodecyl sulphate (SDS) surfactant solution, is applied to the separation layer (Nafion@RC membrane), enabling plasma separation that subsequently flows into the adjacent etalon@RC sensing region. The incorporation of Nafion and microgel etalon layers enhances capillary transport through the RC substrate, facilitating efficient passive liquid delivery within the integrated separation-sensing architecture. Glucose binding induces microgel swelling, producing a quantifiable redshift in the corresponding reflectance spectra. Selectivity studies performed with physiologically relevant concentrations of ascorbic acid (0-2.0 mg dL-1) and fructose (0-1.5 mg dL-1) showed no measurable spectral response, owing to Nafion-mediated electrostatic rejection of charged interferents and the etalon's intrinsic detection limits. Our results demonstrate a compact, low-cost separation-sensing platform capable of selective, real-time glucose sensing, highlighting its potential for next-generation point-of-care diagnostics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Separation-sensing Etalon@lateral flow assays for selective glucose sensing — Science Skim