Laser-Induced Graphene Paper-Based Microfluidic Platform for Dual-Mode Electrochemical and Colorimetric Detection of Glucose.
Che-Liang Yeh, Syed Atif Ali, Wen-Ti Wu, Hsiung-Lin Tu
Institute of Chemistry, Academia Sinica, Nankang, Taipei 11529, Taiwan.
Key points
From the paper's conclusion- Here, we present a foldable dual-mode microfluidic paper-based analytical device (DM-μPAD) that integrates laser-induced graphene (LIG)-based electrochemical sensing with enzyme-mediated colorimetric detection.
Abstract
Microfluidic paper-based analytical devices (μPADs) provide an attractive platform for diagnostics owing to their low cost, passive fluid transport, and ease of fabrication. However, integrating dual-sensing capabilities into a single paper device while maintaining a simple manufacturing process remains challenging. Here, we present a foldable dual-mode microfluidic paper-based analytical device (DM-μPAD) that integrates laser-induced graphene (LIG)-based electrochemical sensing with enzyme-mediated colorimetric detection. A straightforward laser-patterning strategy was used to fabricate LIG electrodes directly patterned onto the polyimide tape-covered cellulose paper via a one-step laser engraving process, forming a conductive graphene network that serves as an electrochemical sensing module. A screen-printing process was used to form hydrophobic perfluoropolyether barriers, which define capillary-driven microfluidic channels that guide sample transport between sensing regions. The folded architecture enhances fluid-electrode interaction and enables simultaneous electrochemical and colorimetric measurements within a single analytical platform without electrode transfer or complex assembly. This dual-readout technique provides cross-validation of results to enhance detection reliability. The proposed DM-μPAD demonstrated good selectivity against common nonspecific compounds, a wide linear detection range of 0.01 to 3.0 mM, and a low detection limit of 9.23 μM in the electrochemical mode, while displaying a dynamic detection range of 0.1 to 2.0 mM with a detection limit of 57.9 μM in the colorimetric mode. Furthermore, the platform maintained high reproducibility, mechanical flexibility, and environmental stability. This work highlights the potential of laser-induced graphene-based paper microfluidics as a versatile platform for developing portable, cost-effective, and multiplexed biosensing devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microfluidic Paper-Based Devices at the Edge of Real Samples: Fabrication Limits, Hybrid Detection, and PerspectivesMicromachines · 2026
- Multi-potential laser-induced graphene fluidic paper-based array for in-flow differential analysis of phenolic compoundsTalanta · 2026
- Development of an immersion-type hydrogel-integrated microfluidic glass fiber-based analytical device and its application to smartphone-assisted glucose colorimetric assay.Talanta · 2026
- Efficient fabrication of paper-based microfluidic biosensors incorporating laser-induced graphene for label-free electrochemical immunoassays.Mikrochimica acta · 2026
- Progress toward real-world diagnostic applications of microfluidic paper-based analytical devices (μPADs)Lab on a Chip · 2026
- Rapid fabrication of customizable laser-induced graphene microelectrode arraysAPL Electronic Devices · 2026