Interface-Tailored Hydrogel Microneedle Array Patch with Laser-Engraved Graphene Electrodes for Continual In Vivo Interstitial Fluid Monitoring
Ziyu Yin, Hao Li, Yuanting Xie, Yelan Xiao, Xinghui Li, Lei Su, Xueji Zhang
Key points
From the paper's conclusion- The patch integrates a methacrylated hyaluronic acid hydrogel microneedle array patch (HMAP) with a laser-engraved graphene (LEG) multichannel electrochemical sensor through a MeHA hydrogel interlayer.
Abstract
Microneedle-based interstitial fluid (ISF) analysis has advanced rapidly for wearable healthcare monitoring, yet the hydrogel−electrode junction connecting microneedles to electrochemical transducers remains poorly characterized. Herein, a fully flexible electrochemical patch for dual-biomarker (glucose/Na+) monitoring in ISF is reported. The patch integrates a methacrylated hyaluronic acid hydrogel microneedle array patch (HMAP) with a laser-engraved graphene (LEG) multichannel electrochemical sensor through a MeHA hydrogel interlayer. Glucose is transduced amperometrically at −0.1 V versus Ag/AgCl using a Prussian blue/nickel hexacyanoferrate-mediated glucose oxidase interface. Na+ is transduced potentiometrically using a solid-contact ion-selective electrode incorporating poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) as the ion-to-electron transducer. The interlayer concentration and dispensed volume are optimized based on the apparent interfacial resistance measured after HMAP integration. The selected interlayer formulation exhibited an apparent interfacial resistance of 17.2 Ω, approximately 3.8-fold lower than that of the highest-resistance formulation tested (65.5 Ω). Geometrically normalized amperometric sensitivity is also preserved after HMAP integration. In normoglycemic and streptozotocin-induced diabetic rats (n = 3 per model), the glucose mean absolute relative differences (MARDs) were 18.8% and 33.1%, with mean biases (patch−reference) of +0.81 and +1.90 mM, respectively. Corresponding Na+ MARDs were 3.5% and 2.8%, with mean biases of +0.79 and −3.67 mM. Diabetic glucose estimates relied on out-of-range baseline anchoring, exceeded references by 36−60% at 150−180 min, and were interpreted descriptively. These findings highlight hydrogel−electrode interface optimization as a strategy for improving microneedle-based electrochemical sensing and support further development of the HMAP−LEG patch for wearable biosensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Supramolecular wearable patch for continuous non-invasive blood glucose monitoringSupramolecular Materials · 2026
- Hydrogel microneedle patch for low-cost, colorimetric, continuous glucose monitoring.bioRxiv : the preprint server for biology · 2026
- A wearable paper-based SGR/MCC microneedle array sensor for continuous glucose monitoringMicrosystems & Nanoengineering · 2026
- A Modification-Free Microneedle-Integrated Printed Electrochemical Sensor for Uric Acid Detection in Artificial Skin.ACS applied bio materials · 2026
- Single-use microneedle biosensor for detecting clinically relevant glucose in interstitial fluidBiosensors and Bioelectronics · 2026
- Regenerable, closed-loop, nonenzymatic continuous glucose monitoring enabled by in situ electrochemical interfacial alkalinization.Nature communications · 2026