Capillary-Driven Surface-Enhanced Raman Scattering Hollow Microneedle Patch for Glucose and pH Sensing in Interstitial Fluids.
MinWook Park, Kyuil Chung, Young-Seong Kim, Jeon Woong Kang, Joong Yeon Lim
Department of Mechanical, Robotics, and Energy Engineering, Dongguk University, Seoul04620, Republic of Korea. · Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts02139, United States.
Key points
From the paper's conclusion- Here, we present an integrated, capillary-driven hollow microneedle (HMN) patch that combines passive fluid collection, nitrocellulose (NC) filtration, and surface-enhanced Raman scattering (SERS) sensing of glucose and pH.
Abstract
Minimally invasive monitoring of interstitial fluid (ISF) biomarkers requires reliable sample collection and molecular analysis without external pumping. Here, we present an integrated, capillary-driven hollow microneedle (HMN) patch that combines passive fluid collection, nitrocellulose (NC) filtration, and surface-enhanced Raman scattering (SERS) sensing of glucose and pH. A three-dimensionally printed hydrophilic HMN structure enables skin access and capillary transport, while a flexible and optically transparent substrate permits Raman interrogation from the backside. The SERS substrate was fabricated by Langmuir-Blodgett assembly of four layers of silver-coated gold nanorods (GNR@Ag) on polydimethylsiloxane to create dense plasmonic hotspots. The substrate exhibited good spatial uniformity (RSD = 8.4%) and interbatch reproducibility (RSD = 4.8%). Functionalization with 4-mercaptophenylboronic acid and 4-mercaptobenzoic acid generated glucose- and pH-responsive signals, respectively. Glucose-dependent SERS responses were calibrated up to 30 mM (R2 = 0.97), and pH sensing was linear across pH 4-8 (R2 = 0.98). The NC filter reduced protein-related interference, and low-power excitation (0.25 mW) maintained spectral stability for 200 s. Crosstalk experiments revealed a pronounced pH dependence in glucose sensing but comparatively limited glucose interference with the pH readout. In mice, the patch exhibited fluid uptake after a 20 min collection period and glucose-dose-dependent SERS responses following intravenous administration. Ex vivo tests using excised mouse skin conditioned on agarose media at different pH values further demonstrated pH-responsive sensing under tissue-contact conditions. These results support the potential of a capillary-driven SERS HMN platform for minimally invasive glucose and pH sensing in ISF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Structure-Regulated Silk Fibroin Microneedle Patches for Minimally Invasive Glucose-Responsive Colorimetric Sensing.ACS biomaterials science & engineering · 2026
- Single-use microneedle biosensor for detecting clinically relevant glucose in interstitial fluidBiosensors and Bioelectronics · 2026
- A Highly Sensitive and Rapid-Response M-Hydrogel SERS Chip for Enrichment Detection of Environmental PollutantsThe Journal of Physical Chemistry C · 2025
- Microneedle-Based Optical Biosensors for Point-of-Care Glucose Monitoring in Interstitial Fluid: Recent Advances, Current Challenges, and Future Perspectives.Biosensors · 2026
- Osmotic Pressure-Actuated Hydrogel Patch for Passive Sweat Extraction and Visual Sweat Glucose Monitoring at Rest.Small (Weinheim an der Bergstrasse, Germany) · 2026
- SERS-Integrated Microneedles: Bridging Nanoplasmonics and Microsampling for Advanced BioanalysisACS Sensors · 2025