Talanta

Analytical quality by design for electrochemical nanostructured screen-printed sensor development: uric acid detection in saliva for diagnosis and monitoring of chronic diseases.

Sara Belardinelli, Benedetta Pasquini, Giulia Selvolini, Sandra Furlanetto, Giovanna Marrazza

Department of Chemistry "Ugo Schiff", University of Florence, Via Della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy. · Department of Chemistry "Ugo Schiff", University of Florence, Via Della Lastruccia 3, Sesto Fiorentino (FI), 50019, Italy. Electronic address: giovanna.marrazza@unifi.it.

Key points

From the paper's conclusion
  • The synergy between the PAsp/AuNPs nanocomposite and AQbD-driven optimization represents the main novelty of this work, providing a promising electrochemical platform for uric acid detection.

Abstract

The aim of this study is to develop an electrochemical sensor to determine uric acid levels in saliva, with the ultimate goal of designing a rapid, sensitive and non-invasive diagnostic device. To this end, easy-to-manufacture, disposable graphite screen-printed electrodes (GSPEs) were used as transducers, as they can be easily applied for a rapid, in situ analysis. The working electrode surface was modified with poly(l-aspartic acid) and gold nanoparticles (AuNPs) to enhance the electrochemical performance of the sensor. The optimization process was carried out following the analytical quality by design framework where design of experiments was used for a screening phase and response surface methodology. A method operable design region was defined at a probability level of 99% to ensure robustness against experimental variability. The sensor surface was characterized by cyclic voltammetry and electrochemical impedance spectroscopy techniques in presence of [Fe(CN)6]4-/3- reversible redox couple. The electrochemical behavior of the nanocomposite sensor towards UA oxidation was assessed by differential pulse voltammetry in phosphate-buffered saline solution at the physiological salivary pH of 6.8. The sensor response was found to be linearly related to UA concentration in the range 0-100 mg/L, with a detection limit of 31 μg/L and a quantification limit of 103 μg/L. The synergy between the PAsp/AuNPs nanocomposite and AQbD-driven optimization represents the main novelty of this work, providing a promising electrochemical platform for uric acid detection. Preliminary experiments in lab-prepared synthetic saliva and a commercial saliva substitute revealed significant matrix-dependent effects on analytical recovery. Although sample dilution improved analytical sensitivity and recovery, particularly in the commercial saliva substitute, substantial matrix effects persisted, especially in lab-prepared synthetic saliva. These findings highlight the potential of the proposed platform for non-invasive uric acid monitoring while identifying the analytical challenges that must be addressed before its application to real clinical samples.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers