Ultra-sensitive real-time monitoring of intraocular pressure with an integrated smart contact lens using parity-time symmetry wireless technology
Te Xiao, Hanzhe Zhang, Taiki Takamatsu, Atsushige Ashimori, Saman Azhari, Kazuhiro Kimura, Takeo Miyake
Waseda University · Yamaguchi University
Key points
From the paper's conclusion- These findings highlight the platform’s potential for long-term, non-invasive IOP monitoring, thus making a significant contribution to early diagnosis and treatment of glaucoma.
Abstract
In recent years, smart contact lenses as a type of wearable device have attracted significant attention in health monitoring and disease detection. In this study, we combine a resistive sensor based on a cracked PEDOT: PSS structure with a 70 MHz double-loop gold antenna, enabling high-precision and continuous measurement of intraocular pressure (IOP). By comprehensively optimizing the sensor design, device structure, and wireless detection system, we achieved a sensitivity of 47.31 Ω/mmHg—approximately 15 times higher than conventional approach, corresponding to a resistance change 183 times larger. Both in vitro wireless IOP measurements of a porcine eye and in vivo wireless IOP measurements of rabbit eyes altered by microbead injection, using a commercial tonometer and a fabricated sensor lens, showed a strong correlation with R² values of 93% and 97%, respectively. These findings highlight the platform’s potential for long-term, non-invasive IOP monitoring, thus making a significant contribution to early diagnosis and treatment of glaucoma.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact LensAdvanced Materials Technologies · 2026
- Real-time intraocular pressure monitoring and responsive drug release in preclinical models by an all-polymer smart contact lensScience Translational Medicine · 2026
- Flexible Transparent Capacitive Pressure Sensors for Multimodal Ophthalmic Monitoring: Intraocular Pressure Assessment, Movement Disorder Diagnosis, and Eye‐Tracking Human–Computer Interaction SystemAdvanced Functional Materials · 2025
- Review on Intraocular Pressure-Sensing Systems from Fabrication to Applications.ACS sensors · 2026
- Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoringarXiv · 2026
- Low-power through-body communications for smart contact lenses.Biomedical optics express · 2026