Stretchable Wrinkled‐Gold Antenna for High‐Sensitivity Intraocular Pressure Monitoring Smart Contact Lens
Te Xiao, Saman Azhari, Hanzhe Zhang, Yang Cui, Bingfu Liu, Taiki Takamatsu, Dingliang Xu, Atsushige Ashimori,
Key points
From the paper's conclusion- The results show that the sensor's sensitivity is 0.54 MHz·mmHg −1 in the balloon model and 0.25 MHz·mmHg −1 in the ex vivo porcine eye, with a good linear relationship between IOP changes and resonance frequency shifts.
Abstract
Glaucoma is the main cause of irreversible blindness worldwide, and it is closely related to intraocular pressure (IOP). However, single or short‐term IOP measurements cannot fully reflect the biomechanical environment in the eye and the risk of disease progression. Therefore, continuous daily IOP monitoring is very important for the early diagnosis and long‐term treatment of glaucoma. To solve this problem, this study proposes a smart contact lens sensor that combines the Inductor‐Capacitor resonant circuit principle with a sandwich‐structured, wrinkled gold antenna for wireless IOP monitoring. By structurally modifying conventional materials, the device can flexibly adapt to eyeball deformation while maintaining excellent electrical stability. The results show that the sensor's sensitivity is 0.54 MHz·mmHg −1 in the balloon model and 0.25 MHz·mmHg −1 in the ex vivo porcine eye, with a good linear relationship between IOP changes and resonance frequency shifts. IOP was also successfully monitored in vivo using a live rabbit. Cytotoxicity experiments show that cell survival exceeds 99%, indicating good biocompatibility of the device at the cellular level. This study provides a new technical direction for integrating contact lens sensors with wearable devices, such as smart glasses, to enable continuous, non‐invasive IOP monitoring in daily life.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultra-sensitive real-time monitoring of intraocular pressure with an integrated smart contact lens using parity-time symmetry wireless technologynpj Flexible Electronics · 2026
- Real-time intraocular pressure monitoring and responsive drug release in preclinical models by an all-polymer smart contact lensScience Translational Medicine · 2026
- Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoringarXiv · 2026
- Flexible Transparent Capacitive Pressure Sensors for Multimodal Ophthalmic Monitoring: Intraocular Pressure Assessment, Movement Disorder Diagnosis, and Eye‐Tracking Human–Computer Interaction SystemAdvanced Functional Materials · 2025
- Design and Preclinical Validation of an Eyeglass-Coupled Perilimbal Antenna for Retinal Prostheses With a Biocompatible Graft TechniqueTranslational Vision Science & Technology · 2026
- Review on Intraocular Pressure-Sensing Systems from Fabrication to Applications.ACS sensors · 2026