Review on Intraocular Pressure-Sensing Systems from Fabrication to Applications.
Yun Zheng, RuiYang Wang, JunXuan Li, Hong Zhou, Tie Li, Yong Tao, Zhishan Yuan
School of Electro-Mechanical Engineering, Guangdong University of Technology, Guangzhou510006, China. · Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences , Shanghai200050, China.
Key points
From the paper's conclusion- Additionally, the diverse applications of IOP sensors in disease diagnosis and therapeutic management are discussed, underscoring their potential for personalized and precision medicine, alongside the challenges remaining in their clinical translation.
Abstract
Intraocular pressure (IOP) is amenable to direct regulation and a critical indicator for numerous ocular disorders. Continuous, long-term IOP monitoring provides indispensable clinical data, supporting early diagnosis, risk stratification, and personalized treatment. This review comprehensively summarizes the working principles, key performance metrics, and clinical progress of wearable and implantable IOP sensors. The text elucidates the structural integration of wireless power supplies, signal transmission, and artificial intelligence within wireless IOP monitoring systems. Furthermore, manufacturing and optimization strategies are highlighted, and the considerable advantages of nanomaterials and micro/nanostructures are comprehensively summarized, emphasizing their crucial role in current IOP monitoring devices. Additionally, the diverse applications of IOP sensors in disease diagnosis and therapeutic management are discussed, underscoring their potential for personalized and precision medicine, alongside the challenges remaining in their clinical translation. Finally, current bottlenecks and limitations are addressed, outlining potential solutions, future trends, and potential breakthroughs in next-generation IOP monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultra-sensitive real-time monitoring of intraocular pressure with an integrated smart contact lens using parity-time symmetry wireless technologynpj Flexible Electronics · 2026
- Implanted intracranial pressure sensors: mechanisms, fabrication, and system integration.Nanoscale horizons · 2026
- Flexible Transparent Capacitive Pressure Sensors for Multimodal Ophthalmic Monitoring: Intraocular Pressure Assessment, Movement Disorder Diagnosis, and Eye‐Tracking Human–Computer Interaction SystemAdvanced Functional Materials · 2025
- Nanoparticle-Mediated and Nanoengineered Drug Delivery for Glaucoma: Preclinical Evidence, Early Human Feasibility, and Translational Challenges.Pharmaceuticals (Basel, Switzerland) · 2026
- Real-time intraocular pressure monitoring and responsive drug release in preclinical models by an all-polymer smart contact lensScience Translational Medicine · 2026
- The rise of modern tonometry: the evolution of intraocular pressure measurement.Expert review of medical devices · 2026