Online circular contrast perimetry performed in glaucoma patients in Sub-Saharan Africa: a multi-centre comparative study in Nigeria.
Olusola Olawoye, Joshua Meyerov, Deus Bigirimana, Tarela Frederick Sarimiye, Adaora Chinwendu Okudo, Aisha Sheriff Kalambe, Kuburat Oluwatoyin Adenrele, Chimdia Ogbonnaya,
Department of Ophthalmology, College of Medicine, University of Ibadan, Ibadan, Nigeria. · Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, VIC, Australia. joshuameyerov@gmail.com.
Key points
From the paper's conclusion- OCCP demonstrates consistent moderate agreement with SAP for MD, with similar reliability. As a potential screening and surveillance tool, OCCP could be used to substantiate visual field testing in SSA, especially where perimetry availability is limited.
Abstract
BACKGROUND/OBJECTIVES: Online circular contrast perimetry (OCCP) provides visual field testing on any computer or tablet, without additional hardware. Its performance has not been evaluated in an African cohort. This study compared the performance of OCCP to standard automated perimetry (SAP) in a cohort of Nigerian patients with glaucoma. SUBJECTS/METHODS: Across 404 patients (198 males, 206 females), OCCP mean deviation (MD) and pattern standard deviation (PSD) were compared with SAP using paired analyses, Bland-Altman plots, intraclass correlation coefficients (ICC) and Pearson correlation. The correlation between MD and vertical cup-to-disc ratio (VCDR) was assessed using linear regression. Reliability indices, including fixation losses (FL), false positives (FP), and false negatives (FN), were also compared. RESULTS: Mean OCCP MD was higher than SAP in both eyes (p < 0.001). Bland-Altman analysis demonstrated a positive bias toward higher MD values with OCCP (1.09-1.53 dB), while ICCs indicated moderate reliability and correlation with SAP (0.52-0.53). MD showed stronger correlations with VCDR for OCCP than for SAP (r = -0.41 to -0.48 vs -0.32 to -0.41), although these differences were not statistically significant. Mean PSD values were similar between devices with minimal bias (-0.10 to -0.16 dB); however, agreement and correlation were poor (ICC 0.39; r = 0.39-0.40). Reliability indices (FL, FP, FN) were comparable between OCCP and SAP. CONCLUSIONS: OCCP demonstrates consistent moderate agreement with SAP for MD, with similar reliability. As a potential screening and surveillance tool, OCCP could be used to substantiate visual field testing in SSA, especially where perimetry availability is limited.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Anxiety Levels in Glaucoma Patients Undergoing Standard Automated Perimetry and Online Circular Contrast Perimetry.Journal of glaucoma · 2026
- Evaluation of the Perimouse Online Suprathreshold Visual Field Test for Glaucoma Screening in a Chinese Population: A Comparison with the Humphrey Field Analyzer.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Comparison of the Melbourne rapid fields-web device-independent online perimeter and the octopus 600 perimeter in glaucoma patients.Frontiers in ophthalmology · 2026
- Comparison of 24-2 and 24-2C Visual Field Testing in Eyes with Ocular Hypertension.Medicina (Kaunas, Lithuania) · 2026
- Macular microvascular assessment in glaucoma: Tool output comparison and intersession reliability.Optometry and vision science : official publication of the American Academy of Optometry · 2026
- OCT-Derived Expected Visual Field Function for Quantifying Directional Structure-Function Discordance in Glaucoma and Ocular Hypertension.Diagnostics (Basel, Switzerland) · 2026