Diagnostics (Basel, Switzerland)

OCT-Derived Expected Visual Field Function for Quantifying Directional Structure-Function Discordance in Glaucoma and Ocular Hypertension.

İlknur Tuncer Fırat, Murat Fırat, Hacı Erbalı, Taner Tuncer

Department of Ophthalmology, Faculty of Medicine, Inonu University, 44240 Malatya, Türkiye. · Department of Ophthalmology, Faculty of Medicine, Malatya Turgut Ozal University, 44210 Malatya, Türkiye.

Observational · n=592

Key points

From the paper's conclusion
  • Conclusions: Comparing measured visual field function with eye-specific OCT-derived expected function provides a quantitative framework for describing the magnitude and direction of structure–function disagreement.

Abstract

Background/Objectives: To develop an OCT-based framework that estimates the visual field function expected from an eye's structural profile and quantifies the direction and magnitude of disagreement between structure-derived expected function and the actually measured visual field in glaucoma and ocular hypertension. Methods: This retrospective study included 592 patients, 893 unique eyes, and 1100 eye-visit samples with matched Humphrey Field Analyzer 24-2 visual field testing and peripapillary OCT imaging. Separate models estimated the MD and PSD expected from OCT-derived structural measurements and prespecified nonfunctional covariates, without using measured visual field variables or visual field reliability indices as model inputs. For each eye, the measured MD and PSD were compared with these eye-specific structure-derived expectations. Direction-oriented prediction errors were standardized using the training out-of-fold distributions and combined into a continuous discordance score. Training-derived cutoffs were then used to define structure-worse-than-function (SWF), concordant, and function-worse-than-structure (FWS) strata, which were applied unchanged to the independent test set. Results: In the independent test set, 119 eyes (55.9%) were concordant, 43 (20.2%) were SWF, and 51 (23.9%) were FWS. FWS eyes showed substantially worse MD and higher PSD, while patient-cluster-aware analyses identified significant differences in temporal, superior, and inferior RNFL thickness among the directional strata. Random forest was selected as the best-performing classifier. The base model achieved an accuracy of 0.667, balanced accuracy of 0.567, macro-F1 score of 0.582, and one-vs-rest macro AUC of 0.794. Conclusions: Comparing measured visual field function with eye-specific OCT-derived expected function provides a quantitative framework for describing the magnitude and direction of structure-function disagreement. This approach is intended to complement, rather than replace, measured perimetry.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

OCT-Derived Expected Visual Field Function for Quantifying Directional Structure-Function Discordance in Glaucoma and Ocular Hypertension — Science Skim