Solvent Leveling Explains Supercharging in Electrospray Ionization Mass Spectrometry.
Boyu Zhao, Reid O'Brien Johnson, Muhammad Zenaidee, Wonhyeuk Jung, Joseph A Loo, Rachel R Ogorzalek Loo
Department of Chemistry and Biochemistry, University of California-Los Angeles, Los Angeles, California90095, United States.
Key points
From the paper's conclusion- Hence, the recipe for increasing charge in positive ion mode is to make the protonated solvent into a stronger acid (equivalent to reducing the neutral solvent's basicity).
Abstract
Supplementing standard electrospray ionization (ESI) solvents with specific low-volatility organic compounds (e.g., sulfolane or any positional isomer of nitrobenzyl alcohol) increases biomolecular analyte charge for mass spectrometry in the phenomenon known as supercharging. Controversial mechanisms responsible for increasing charge are considered, and the data is found to correlate highly to solvent leveling; i.e., protonated solvent is the strongest acid in a solution because any stronger acid simply dissociates to protonate more solvent. Hence, the recipe for increasing charge in positive ion mode is to make the protonated solvent into a stronger acid (equivalent to reducing the neutral solvent's basicity). That change is accomplished by adding involatile, weak bases to the solvent. A secondary effect of weak base additives is to suppress the solution-phase ionization of weak acid residues; e.g., reducing opposite charging. Here the abilities of analogous compounds to increase or decrease charging in positive ion mode ESI are predicted from experimentally measured basicities. Consistently, amides, nitriles, and pyrazoles more basic than water reduced the average charge of protein analytes electrosprayed from denaturing solutions, while analogues less basic than water increased the average charge, establishing the veracity of solvent leveling as a supercharging mechanism. In other words, reducing the charge departing on solvent leaves more charge for the protein analyte.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Is the Signal Worth the Noise? A Practical Guide to Charge-Tagging for ESI-MS Reaction MonitoringACS Organic & Inorganic Au · 2026
- Multi-Laboratory Assessment Reveals Variable Ion Species Profiles in Electrospray Ionization Mass SpectrometryJournal of the American Society for Mass Spectrometry · 2026
- Performance comparison of UniSprayTM and electrospray ionisation coupled to ion-mobility high-resolution mass spectrometer for screening of organic pollutants in water matrices.Journal of chromatography. A · 2026
- An Isotope-Induced Polarity Bias in Electrospray Ionization Mass Spectrometry.ACS measurement science au · 2026
- What Determines the Charge State Distribution of Proteins Electrosprayed from Non-Denaturing Solutions?Analytical chemistry · 2026
- An Energetic-Control Framework for Electrospray Ionization Using Thermometer Ions.Journal of the American Society for Mass Spectrometry · 2026