Beyond Sensitivity: Materials and Biointerface Design Rules for Aptamer-Enabled Smart Contact Lenses.
Xiaolong Zhang, Yangzhi Zhu
Biomedical Device Center, Terasaki Institute for Biomedical Innovation, Los Angels, California 90064, United States.
Key points
From the paper's conclusion- We distinguish physiological concentration ranges, established lens benchmarks, and provisional engineering criteria, and examine flow, deformation, receptor saturation, nuclease stability, anchoring chemistry, fouling, optical and oxygen requirements, thermal effects, calibration, sterilization, shelf life, and regulatory considerations.
Abstract
Smart contact lenses are emerging as platforms for continuous molecular monitoring at the ocular surface, yet their performance is often evaluated by detection limits measured in static buffer. During on-eye operation, signals are shaped before transduction by tear renewal, blinking, hydrogel partitioning, surface deposition, oxygen transport, receptor degradation, and interfacial drift. Aptamers offer sequence-defined recognition of metabolites, proteins, hormones, and drugs, but immobilization in hydrated lens materials can alter target accessibility, conformation, binding kinetics, and operational lifetime. In this perspective, we treat the tear-lens-aptamer biointerface as the functional sensing interface. We distinguish physiological concentration ranges, established lens benchmarks, and provisional engineering criteria, and examine flow, deformation, receptor saturation, nuclease stability, anchoring chemistry, fouling, optical and oxygen requirements, thermal effects, calibration, sterilization, shelf life, and regulatory considerations. This framework links material design to reversible, stable, and clinically interpretable measurements while preserving the optical, mechanical, and physiological performance required for a wearable lens.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time intraocular pressure monitoring and responsive drug release in preclinical models by an all-polymer smart contact lensScience Translational Medicine · 2026
- Contact lens with stretchable distributed-feedback laser for intraocular pressure monitoringarXiv · 2026
- Optical Contact Lenses BiosensorsACS Sensors · 2025
- Wearable Contact Lenses for Advanced Ocular Drug Delivery: Progress and ChallengesAdvanced Functional Materials · 2025
- Ultra-sensitive real-time monitoring of intraocular pressure with an integrated smart contact lens using parity-time symmetry wireless technologynpj Flexible Electronics · 2026
- Validation of Aptamer-Protein Interactions by Biolayer Interferometry: A Study of 88 Candidate Molecules.International journal of molecular sciences · 2026