Microbial and Water Quality Dynamics in a Utilidor-Housed Subsurface Drinking Water Distribution System Under Low-Use Conditions.
Srijan Aggarwal, Kirsten Grond, Theresa Miller, Fayzul Kabir, Ibnul Hasan, Shayna Matson, Subhabrata Dev, Devin M Drown
Civil, Geological, and Environmental Engineering, University of Alaska Fairbanks, Fairbanks, Alaska, 99775, USA. · Institute of Arctic Biology, University of Alaska Fairbanks, Fairbanks, Alaska, 99775, USA.
Key points
From the paper's conclusion- These findings demonstrate that elevated temperatures and disinfectant decay may influence microbial communities and favor pathogen-associated taxa under low use.
Abstract
Cold-region utilidor-based drinking water distribution systems (DWDSs) are considered climate-resilient infrastructure but remain poorly characterized. Elevated temperatures and water age in such systems may accelerate disinfectant decay and microbial growth. We investigated water chemistry and microbiomes in a utilidor-housed subsurface DWDS serving a mixed-use sub-Arctic community during low demand following partial closure. Main and premise plumbing samples were collected over eight events spanning 14 months. Physicochemical measurements accompanied 16S rRNA gene amplicon sequencing. Temperatures increased from 7.2°C at the inlet to 31.9°C distally, while free chlorine residual declined significantly. Alpha diversity increased with distance and correlated negatively with disinfectant residual and dissolved oxygen. Microbial community composition differed significantly by location and time; Proteobacteria dominated most sites. Genera containing opportunistic pathogens included Legionella (80.7%), Mycobacterium (24.7%), and Pseudomonas (32.5%), with significant associations with total dissolved solids, nitrate, and dissolved organic carbon. These findings demonstrate that elevated temperatures and disinfectant decay may influence microbial communities and favor pathogen-associated taxa under low use. Utilidor-based DWDSs may, therefore, indicate vulnerabilities in buried systems under climate-driven warming and reduced demand. Results highlight the need for design and operational strategies addressing thermal control, water age, and disinfectant stability to protect drinking water quality in climate-stressed systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Six years later: tracking water quality and microbiome shifts from influent to tap in a large public building.Water research · 2026
- Spatial and Temporal Variation in Antibiotic Resistance Genes and Bacterial Community Composition in a Drinking Water Supply System: From Source to Tap.Microorganisms · 2026
- Microbial Growth Curve Framework Provides Insights for Controlling Opportunistic Pathogens in Building PlumbingACS ES&T Water · 2026
- Unraveling the microbial characteristics in different microbial habitats within the secondary water supply systems.Environmental pollution (Barking, Essex : 1987) · 2026
- Stagnant plumbing: Drinking water quality responses to stagnation in controlled systems.Water research · 2026
- Assessment of Microbial Contamination in Stagnant Water from Dental Unit ReservoirsApplied Biosciences · 2026