Assessment of Microbial Contamination in Stagnant Water from Dental Unit Reservoirs
Isabelly Karina Missi de Souza, Gabriel Paranhos Tanaka, Letícia de Souza Moda-Monteiro, Amanda Carolina Souza Delfino da Rocha, Tatiana Areas da Cruz, Viviane de Cássia Oliveira, Evandro Watanabe
Key points
From the paper's conclusion- These findings demonstrate that microbial contamination may persist in stagnant water from dental unit reservoirs despite routine chemical disinfection protocol and reinforce the importance of continuous microbiological monitoring and effective management of dental unit water systems.
Abstract
Water stagnation in dental unit reservoirs may be associated with increased microbial contamination and potential exposure to opportunistic microorganisms, particularly among medically vulnerable patients and dental healthcare professionals. This study aimed to assess the microbiological quality of stagnant water collected from reservoirs of dental units at a tertiary academic school of dentistry by determining bacterial and coliform counts and detecting and morphologically identifying filamentous fungi. Although 152 dental units were available across the five clinics, only 106 reservoirs contained stagnant water at the time of sampling and could therefore be included in the microbiological analysis. Water samples were analysed using Petrifilm™ AC (total aerobic bacteria), EC (Escherichia coli and total coliforms), and YM (yeasts and moulds) plates, with results expressed as colony-forming units per millilitre (CFU/mL). Filamentous fungi were identified based on macroscopic and microscopic morphological characteristics following subculture onto Potato Dextrose Agar. Fifteen samples showed estimated aerobic bacterial counts exceeding 500 CFU/mL, three tested positive for total coliforms, and filamentous fungal growth was detected in nine samples. The fungal genera identified included Aspergillus, Absidia, Cunninghamella, and Trichophyton. Notably, Trichophyton rubrum was identified in one stagnant water sample from a dental unit reservoir. To the best of our knowledge, this finding has not previously been reported in dental unit water systems, although it should be interpreted with caution because the identification was based exclusively on morphological characteristics and was not confirmed by molecular methods. These findings demonstrate that microbial contamination may persist in stagnant water from dental unit reservoirs despite routine chemical disinfection protocol and reinforce the importance of continuous microbiological monitoring and effective management of dental unit water systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Waterborne and Opportunistic Microorganisms in Dental Water Systems: A Scoping Review.Microorganisms · 2026
- Microbial contamination patterns in dental unit waterlines and evaluation of a centralized automated cleaning and disinfection system .Neuro endocrinology letters · 2026
- Detection of non-tuberculous mycobacteria and other bacterial pathogens in dental unit waterlines, 2024, Germany: a microbiological single-centre studyPubMed · 2026
- Global variability in dental unit waterline safety standards: bridging the gap between guidelines and practice.Frontiers in oral health · 2026
- Antimicrobial Susceptibility Patterns of Pathogenic Microorganisms Isolated from Sanitary Facilities in Referral Hospitals at Abakaliki, Ebonyi StateInternational Journal of Pathogen Research · 2026
- Dental unit waterlines in Israel: evidence of widespread microbial contamination and a need for national regulation.Israel journal of health policy research · 2026