Microbial Growth Curve Framework Provides Insights for Controlling Opportunistic Pathogens in Building Plumbing
Tolulope Odimayomi, Amy Pruden, Marc Edwards
Vanda Institute
Key points
From the paper's conclusion- We extended this observation to develop a framework to understand how various controls and operating conditions act to stop (e.g., cold temperatures, disinfectant) or reset (e.g., pasteurization in water heaters killing microbes and recycling nutrients) the growth curve as a function of WRT.
Abstract
High Resolution Image Download MS PowerPoint Slide The perception that high water retention time (WRT) in buildings increases microbial and pathogen growth drives costly flushing interventions, which lack a scientific framework to guide effective implementation. Here, we evaluate the effect of WRT from 1 to 21 days in an at-scale building plumbing rig with influent chloramine residuals of <0.2–2.5 mg/L as Cl 2 and water heater set points of 40 and 60 °C. We found that the classic microbial growth curve consisting of lag, exponential growth, stationary, and decay phases provided a robust explanation of trends in bulk water total cell counts (TCC) and Legionella pneumophila over a wide range of conditions. We extended this observation to develop a framework to understand how various controls and operating conditions act to stop (e.g., cold temperatures, disinfectant) or reset (e.g., pasteurization in water heaters killing microbes and recycling nutrients) the growth curve as a function of WRT. Bulk water TCC and L. pneumophila reached a consistent peak/plateau at a building WRT of ∼7 days before decaying up to 90% at higher WRT. These findings suggest that recent guidelines recommending weekly flushing of buildings may sometimes be counterproductive and that very high WRT does not necessarily indicate microbial risk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Premise Plumbing "CT" (PPCT) as a Control Parameter for Opportunistic Pathogens.ACS ES&T water · 2026
- Stagnant plumbing: Drinking water quality responses to stagnation in controlled systems.Water research · 2026
- Six years later: tracking water quality and microbiome shifts from influent to tap in a large public building.Water research · 2026
- Long-term control of Legionella pneumophila and Pseudomonas aeruginosa in dental unit waterlines following optimization of a hypochlorous acid-based water safety program.Frontiers in oral health · 2026
- Coupled physicochemical and microbial recovery of aged premise plumbing following water-supply interruption.Water research · 2026
- Microbial and Water Quality Dynamics in a Utilidor-Housed Subsurface Drinking Water Distribution System Under Low-Use Conditions.ACS ES&T water · 2026