Six years later: tracking water quality and microbiome shifts from influent to tap in a large public building.
Mila Otegui, Juan P Maestre, Richard M Niedbala, Evan Williams, Charles J Werth, Lina Sela, Lynn E Katz, Kerry A Kinney
University of Texas at Austin, Maseeh Department of Civil, Architectural and Environmental Engineering, 301 E. Dean Keeton St., Austin, TX, 78712, United States. Electronic address: milagros.otegui.a@utexas.edu. · University of Texas at Austin, Maseeh Department of Civil, Architectural and Environmental Engineering, 301 E. Dean Keeton St., Austin, TX, 78712, United States. Electronic address: juanpedro.maestre@utexas.edu.
Key points
From the paper's conclusion- Overall, this study highlights the temporal changes in water quality in large public buildings following commissioning.
Abstract
Drinking water quality within premise plumbing directly governs human exposure to disinfectant residuals, corrosion byproducts, and opportunistic pathogens, yet its evolution over time remains poorly understood. This gap persists because long-term, full-scale studies that evaluate infrastructure aging alongside water use patterns are rare. Here, we compare disinfectant persistence, metal release, and microbial community structure in a nine-story academic building during commissioning (2018) and six years later (2024). Water samples were collected from the building influent and multiple taps under first-flush and after-flush conditions during Class and Spring Break sampling periods. Although influent monochloramine concentrations were similar between sampling campaigns in 2018 and 2024, tap residuals were higher in 2024, indicating less in-building decay. Dissolved copper concentrations were lower in 2024 than during commissioning, with intermediate measurements collected in 2020 and 2021. Nitrifier-associated taxa were rare in the bulk water, suggesting that bacterially mediated nitrification in the sampled water was unlikely to be a dominant contributor to monochloramine loss. Tap microbial communities differed significantly from the influent communities in 2018, while Class and Spring Break samples differed in 2024. While Mycobacterium had higher estimated abundance in 2018, Legionella did not differ significantly between campaigns or among sample types within either campaign. Overall, this study highlights the temporal changes in water quality in large public buildings following commissioning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Coupled physicochemical and microbial recovery of aged premise plumbing following water-supply interruption.Water research · 2026
- Stagnant plumbing: Drinking water quality responses to stagnation in controlled systems.Water research · 2026
- Microbial and Water Quality Dynamics in a Utilidor-Housed Subsurface Drinking Water Distribution System Under Low-Use Conditions.ACS ES&T water · 2026
- Microbial Growth Curve Framework Provides Insights for Controlling Opportunistic Pathogens in Building PlumbingACS ES&T Water · 2026
- Nitrification control and early microbiome-resistome transitions during permanent conversion from chloramine to free chlorine in a full-scale drinking water distribution system.Water research · 2026
- Unraveling the microbial characteristics in different microbial habitats within the secondary water supply systems.Environmental pollution (Barking, Essex : 1987) · 2026