Online Two-Dimensional Ion Chromatography Coupled with Orbitrap MS for Measuring the Triple Isotopic Composition (δ15N, δ18O, Δ17O) of Nitrate.
Allyson Girard, J David Felix, Hussain Abdulla
Department of Chemistry and Biochemistry, University of North Carolina Wilmington, 601 South College Road, Wilmington, North Carolina28403, United States. · Department of Physical and Environmental Sciences, Texas A&M University-Corpus Christi, 6300 Ocean Drive, Corpus Christi, Texas78412, United States.
Key points
From the paper's conclusion- We applied the optimized method to conduct replicate measurements of NO3− isotopic standards (IAEA-NO-3, USGS-34, and USGS-35) and developed a calibration framework to express Orbitrap-measured ratios on the measurement scales used in conventional stable isotope studies.
Abstract
Stable isotope signatures of nitrate (NO3-) are useful tracers in environmental studies, but high-throughput applications are constrained by the extensive preparatory steps required to convert NO3- to N2O for GC-IRMS analysis. Additionally, most laboratories are limited to δ15N and δ18O analysis, as the determination of Δ17O requires specialized instrumentation. Electrospray ionization (ESI) Orbitrap-MS offers advantages over conventional IRMS by preserving native molecular structures of target analytes; however, existing Orbitrap-MS NO3-isotope techniques rely on the direct infusion of pure analyte solutions and have only been optimized for the analysis of NO3- in methanol. Here, we demonstrate the feasibility of coupling ion chromatography to ESI-Orbitrap for the analysis of NO3- isotopologues in aqueous solutions. MS parameters were optimized to enhance precision, and correction strategies were developed to account for method fractionation effects and instrument drift. We applied the optimized method to conduct replicate measurements of NO3- isotopic standards (IAEA-NO-3, USGS-34, and USGS-35) and developed a calibration framework to express Orbitrap-measured ratios on the measurement scales used in conventional stable isotope studies. Pooled standard deviations for the isotopic standards of 0.9‰, 2.0‰, and 2.0‰ were obtained for δ15N, δ18O, and Δ17O, respectively, with offsets from expected delta values between -0.1 and 0.2‰. This technique enables high-throughput analysis with minimal pretreatment compared to the hours to days required for offline NO3-purification. While these results demonstrate the potential of online IC-ESI-Orbitrap-MS as a practical approach for rapid nitrate isotope analysis, we also outline several avenues for future method improvement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrospray-Orbitrap Analysis of Nitrate and Sulfate Isotopologues in Natural Samples: Performance and Constraints.Analytical chemistry · 2026
- Lessons Learned in Orbitrap MS-Based Isotope Ratio Analysis of Organic Acid MixturesAnalytical Chemistry · 2026
- Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass SpectrometryAnalytical Chemistry · 2025
- δ13C Determination of Benzoic Acid by High-Resolution Orbitrap MS: How Sample Introduction Strategy Governs Accuracy and Precision.Journal of the American Society for Mass Spectrometry · 2026
- Heart-Cutting Two-Dimensional Liquid Chromatography Coupled to ESI-Orbitrap Mass Spectrometry for Simultaneous 13C and 15N Isotopologue Analysis of GlyphosateAnalytical Chemistry · 2026
- Position-Specific Carbon Isotope Analysis of Glucose at Natural Isotope Abundance by Electrospray-Ionization Orbitrap Mass SpectrometryAnalytical Chemistry · 2025