Heart-Cutting Two-Dimensional Liquid Chromatography Coupled to ESI-Orbitrap Mass Spectrometry for Simultaneous 13C and 15N Isotopologue Analysis of Glyphosate
Sarah P. Rockel, Annika Gruhlke, Felix Niemann, Maik A. Jochmann, Torsten C. Schmidt
Key points
From the paper's conclusion- Here, we report the first ESI-orbitrap method enabling 13C and 15N isotope analysis of glyphosate, integrating a heart-cutting two-dimensional liquid chromatography (2D-LC) interface for matrix removal, coelution resolution, and eluent exchange between the aqueous-rich first-dimension mobile phase and the high organic content conditions required for stable electrospray ionisation.
Abstract
Compound-specific stable isotope analysis (CSIA) of organophosphonates has so far been conducted by liquid chromatography-isotope ratio mass spectrometry (LC-IRMS), which requires complete oxidation of the analyte to CO2 and is inherently restricted to δ13C measurements. Simultaneous multi-element isotope analysis, e.g. of 13C and 15N, which would provide complementary mechanistic information on transformation pathways, remains inaccessible by this approach. Electrospray ionisation orbitrap mass spectrometry (ESI-orbitrap) offers a promising alternative, as isotopologue ratios are measured directly on intact molecular ions without conversion interfaces. This enables simultaneous isotope analysis of multiple elements from a single measurement, can provide access to intramolecular isotope information and, in combination with chromatography, allows several analytes to be analysed in complex samples. Here, we report the first ESI-orbitrap method enabling 13C and 15N isotope analysis of glyphosate, integrating a heart-cutting two-dimensional liquid chromatography (2D-LC) interface for matrix removal, coelution resolution, and eluent exchange between the aqueous-rich first-dimension mobile phase and the high organic content conditions required for stable electrospray ionisation. Direct coupling of the second chromatographic dimension to the orbitrap introduced pronounced chromatographic isotope fractionation of approximately 800‰ for δ13C across the eluting peak. Incorporation of a sample loop after the second-dimension column reduced this variation by a factor of approximately 80 within the central region of the delivered peak, where analyte concentration and ion statistics are most stable. The residual variation was attributed to concentration-dependent measurement bias, rather than chromatographic isotope fractionation, establishing injection time averaging as a more robust reference matching criterion than instantaneous total ion current. Under optimised conditions, isotope ratio deviations of −0.07‰ and +0.18‰ were achieved for δ13C and δ15N, respectively. A proof-of-concept separation of glyphosate and AMPA in the second dimension demonstrates the potential for simultaneous multi-analyte isotope analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Online Two-Dimensional Ion Chromatography Coupled with Orbitrap MS for Measuring the Triple Isotopic Composition (δ15N, δ18O, Δ17O) of Nitrate.Analytical chemistry · 2026
- Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass SpectrometryAnalytical Chemistry · 2025
- δ13C Determination of Benzoic Acid by High-Resolution Orbitrap MS: How Sample Introduction Strategy Governs Accuracy and Precision.Journal of the American Society for Mass Spectrometry · 2026
- Stable Carbon Isotope Analysis of PFOA and PFOS Using Orbitrap Mass SpectrometryEnvironmental Science & Technology Letters · 2026
- Intramolecularly Labeled Reference Standards of Sulfamethoxazole for Fragment-Specific Isotope Analysis by Electrospray Ionization Orbitrap Mass SpectrometryJournal of the American Society for Mass Spectrometry · 2026
- Lessons Learned in Orbitrap MS-Based Isotope Ratio Analysis of Organic Acid MixturesAnalytical Chemistry · 2026