Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass Spectrometry

Nora M. Bernet, Cleo Soldini, Timo M. O. Felder, Kristýna Lapčíková, Cajetan Neubauer, Wendy L. Queen, Rälf Kaegi, Federica Tamburini, Thomas B. Hofstetter

原始摘要(英文原文)· Original abstract
High Resolution Image Download MS PowerPoint Slide Orbitrap mass spectrometry with electrospray ionization (ESI-Orbitrap MS) enables 18 O/ 16 O ratio measurements in phosphate and organophosphorus compounds, which offers promising avenues for the study of metabolic, biogeochemical, and environmental processes. While the instrumental feasibility of such 18 O/ 16 O ratio measurements has been shown, the applicability of such analyses in aqueous matrices on multipurpose mass spectrometers remains unaddressed. Here, we (i) evaluated the interplay between instrument parameters and the long-term accuracy and precision of ESI-Orbitrap MS for the determination of δ 18 O(PO 4 ) from H 2 PO 4 – vs PO 3 – fragments of phosphate, (ii) identified properties of methanolic sample solutions that are critical for accurate and precise measurements, and (iii) propose a sample purification procedure for the elimination of matrix-based interferences. In 10 measurement campaigns over two years, we observed a long-term reproducibility of δ 18 O(PO 4 ) within ±2.8‰. Results of in-source fragmentation experiments of H 2 PO 4 – to PO 3 – show excellent agreement of δ 18 O and offer promising opportunities to probe for 18 O/ 16 O ratios in organophosphorus compounds. By investigating the effect of the aqueous matrix and interfering anions on 18 O/ 16 O ratio measurements, we found that a water content exceeding 50 vol % and the presence of oxyanions such as nitrate and sulfate limit measurement accuracy due to interferences of matrix constituents in the ESI source. To overcome these challenges, we evaluated selective phosphate extraction with a zirconium-based metal–organic framework (MOF) as sorbent. The resulting purification procedure allowed for successful extraction and recovery of phosphate from nitrate- and sulfate-containing aqueous solutions, resulting in methanolic phosphate samples that enabled accurate analyses of δ 18 O(PO 4 ) by ESI-Orbitrap MS.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Oxygen Isotope Analyses of Phosphate and Organophosphorus Compounds by Electrospray Ionization Orbitrap Mass Spectrometry — 科研速览 Science Skim