Deep learning denoising and positron range correction of clinical [68Ga]Ga-DOTA-TOC PET images.
Prodromos Gavriilidis, Roel Wierts, Jochem A J van der Pol, Sander Jentjens, Felix M Mottaghy, Michel Koole
Department of Radiology and Nuclear Medicine, Maastricht UMC+, Maastricht, The Netherlands; Research Institute for Oncology and Reproduction (GROW), Maastricht University, Maastricht, The Netherlands; Nuclear Medicine and Molecular Imaging, Department of Imaging & Pathology, KU Leuven, Leuven, Belgium. Electronic address: prodromos.gavriilidis@mumc.nl. · Department of Radiology and Nuclear Medicine, Maastricht UMC+, Maastricht, The Netherlands.
Key points
From the paper's conclusion- This study aimed to evaluate a DL model for simultaneous denoising and 68Ga-specific PRC in clinical [68Ga]Ga-DOTA-TOC PET scans.
Abstract
PET image quality degradation due to positron range effects in high-energy positron-emitting radionuclides such as Gallium-68 (68Ga) can be mitigated by applying positron range correction (PRC). Deep learning (DL) models have been shown to improve image quality by reducing image noise. This study aimed to evaluate a DL model for simultaneous denoising and 68Ga-specific PRC in clinical [68Ga]Ga-DOTA-TOC PET scans. Three different U-Net-based DL models were trained to map reduced-count PET images reconstructed without PRC (25%, 33%, or 50% of acquired counts) to full-count PET images reconstructed with tissue-independent PRC (FC-PRC). The generated reduced-count-enhanced images (RCE-25%, RCE-33%, RCE-50%) were evaluated using the mean standardized uptake value (SUVmean) in liver and lung, noise levels in liver, and maximum standardized uptake value (SUVmax) and contrast-to-noise ratio (CNR) of soft tissue lesions. Three experienced nuclear medicine physicians assessed the overall image quality (OIQ), overall diagnostic confidence (ODC), and lesion detectability (sensitivity, specificity, accuracy). Compared to FC-PRC, RCE-33% and RCE-50% exhibited similar noise, whereas RCE-25% showed substantial residual noise. CNR was reduced for RCE-33% (-5.6%, p=0.001) and RCE-25% (-8.0%, p<0.001), but was comparable for RCE-50%. All reduced-count-enhanced images demonstrated lower SUVmax (RCE-25%: -3.8%, p=0.02; RCE-33%: -7.0%, p<0.001; RCE-50%: -5.2%, p<0.001). RCE-33% and RCE-50% achieved non-inferior OIQ and ODC compared to FC-PRC, while RCE-25% demonstrated only non-inferior ODC. All reduced-count-enhanced images showed high sensitivity, specificity, and accuracy (>90%). The proposed DL-based approach achieved comparable noise and image quality down to 50% of counts. Although it did not outperform the reconstruction-based PRC, its benefit lies in simultaneous denoising and PRC in a single step.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learningEJNMMI Physics · 2026
- Perceptually optimized NPS-based deep learning framework for PET image denoising.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Deep learning denoising and deep learning-augmented contrast enhancement improve ultra-high-resolution photon-counting-detector CCTA image quality.European radiology experimental · 2026
- Feasibility Study of Deep Learning-Driven Image Restoration for Fast, Low-Count [18F]FP-CIT Digital PET/CT.Diagnostics (Basel, Switzerland) · 2026
- Meta-PET: A graininess-modulated test-time adaptive network for low-count PET denoising.Medical image analysis · 2026
- Joint Poisson Reconstruction for Prompt-Gamma-Enabled 68Ga/18F Dual-Isotope Quantitative PET ImagingarXiv · 2026