Feasibility Study of Deep Learning-Driven Image Restoration for Fast, Low-Count [18F]FP-CIT Digital PET/CT.
Sora Baek, Ji Young Kim, Jae Young Joo, Hyung-Ji Kim, Ohyun Kwon, Minkyu Lee, Min-Gwan Lee, Chanrok Park,
Department of Nuclear Medicine, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, 150, Seongan-ro, Gangdong-gu, Seoul 05355, Republic of Korea. · Department of Nuclear Medicine, Hanyang University Medical Center, Hanyang University College of Medicine, 221-1, Wangsimni-ro, Seongdong-gu, Seoul 04763, Republic of Korea.
Key points
From the paper's conclusion- This study evaluated the feasibility of deep learning (DL)-driven image restoration of short-duration [18F]FP-CIT images.
Abstract
Background/Objectives: N-3-[18F]fluoropropyl-2β-carbomethoxy-3β-4-iodophenyl nortropane ([18F]FP-CIT) positron emission tomography/computed tomography (PET/CT) is an effective imaging tool for diagnosing parkinsonism. This study evaluated the feasibility of deep learning (DL)-driven image restoration of short-duration [18F]FP-CIT images. Methods: List-mode data from 202 patients who underwent [18F]FP-CIT PET/CT were reconstructed into 30-s (30sec), 1-min (1min), and reference 10-min (10min) acquisition durations. Patients were divided into training, validation, and test sets in a 6:2:2 ratio. The U-Net model was implemented to generate the DL images from 30sec and 1min data. The visual image quality was assessed using a three-point scale, visual interpretation of striatal dopamine transporter binding patterns, regional standardized uptake value ratios (SUVRs), and quantitative quality metrics including the peak signal-to-noise ratio, root mean squared error, and universal quality index among five series of images: 30sec, 1min, DL-30sec, DL-1min, and 10min. Results: While 30sec and 1min low-count scans showed poor image quality, the DL-driven algorithm showed significant improvement; DL-1min scans achieved excellent ratings in 95% of cases. Concordance with the reference images was 85.0% for visual image quality and 92.5% for visual interpretation in the DL-30sec images, and 97.5% and 92.5%, respectively, in the DL-1min images. Discordant interpretations occurred mainly in patients with atypical parkinsonism. Regional SUVR values and quantitative metrics for the DL-1min images showed good agreement and smaller biases with respect to the reference images, compared with those of DL-30sec images. Conclusions: The DL-driven method generated clinically acceptable [18F]FP-CIT images while reducing acquisition time, with better image quality in the DL-1min than in the DL-30sec images. Concordance in visual interpretation was reduced in the small subgroup of patients with atypical parkinsonism.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acquisition Time-Specific Deep Learning-Guided Image Quality Restoration in Accelerated I-123 DaTSCAN Brain SPECT on a Ring-Shaped CZT-Based Camera.Journal of imaging informatics in medicine · 2026
- Subregional cutoffs in 18F-FP-CIT PET: Comparison of Heuron Brain PET and PMOD.Clinical imaging · 2026
- Deep progressive reconstruction for low-dose ¹⁸F-FDG PET/CT imaging in pediatric patients.Annals of nuclear medicine · 2026
- Acquisition time/dose reduction in pediatric PET imaging using patch-based deep learningEJNMMI Physics · 2026
- Leveraging High-Activity Post-Therapeutic I-131 Scans for Deep Learning Reconstruction of Extremely Sparse Planar Images in Differentiated Thyroid CancerarXiv · 2026
- On the utility of ChatGPT in conducting a literature review on deep learning for dopamine transporter SPECT with [¹²³I]ioflupaneNuklearmedizin - NuclearMedicine · 2026