Within-day temporal dynamics of exhaled breath features during prolonged fasting monitored by SESI-HRMS: a pilot study.
Chencheng Wei, Stefan James Swift, Rafael Riudavets Pui, Stamatios Giannoukos, Renato Zenobi
Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen, 361005, China. · Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, CH-8093, Switzerland.
Key points
From the paper's conclusion- We suggest that fasting duration, sampling time, ambient background, and handling of the sampling interface should all be standardized and reported in future breath metabolomics studies.
Abstract
Fasting is widely used to standardize breath sampling and reduce short-term dietary interference, yet fasting itself is a dynamic physiological state. We investigated the temporal stability of exhaled breath m/z features during prolonged daytime fasting using secondary electrospray ionization coupled with high-resolution mass spectrometry (SESI-HRMS). Three healthy volunteers consumed a standardized evening meal and fasted thereafter; exhaled breath was analyzed the next day from 08:00 to 18:00 (approximately 12.5-22.5 h of fasting) at 15-min intervals in positive and negative ion modes. Targeted analysis showed pronounced increases in the features putatively annotated as protonated acetone and pentanal, with the former consistent with established fasting physiology. Untargeted analysis identified 151 m/z features with significant concordant temporal trends in at least two of the three subjects; 60 remained after applying an ambient-background criterion, and 51 of these retained a consistent trend direction under all four data-processing approaches tested in a normalization sensitivity analysis. Dense longitudinal sampling also revealed abrupt signal changes coinciding with mouthpiece replacement in one participant; this exploratory observation points to a possible, as yet unconfirmed, additional pre-analytical source of variability. Because fasting duration, time of day, and instrument run time progressed together in this design, the observed changes cannot be attributed to fasting alone. These findings suggest that a 'fasted' breath sample may not be temporally invariant. We suggest that fasting duration, sampling time, ambient background, and handling of the sampling interface should all be standardized and reported in future breath metabolomics studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Vivo Real-Time Metabolic Isotopic Tracing via Breath Analysis upon Deuterated Water Ingestion: A Proof-of-Concept Study.ACS central science · 2026
- Long-term performance monitoring of a secondary electrospray ionisation high-resolution mass spectrometry platform using a vapor generator for routine quality control.Analytical methods : advancing methods and applications · 2026
- The Mouthpiece Type Factor: Impact of Filter Selection on Secondary Electrospray Ionisation High-Resolution Mass Spectrometry (SESI-HRMS) Breath Profiles.Journal of breath research · 2026
- Stability of Volatile Organic Compounds in Exhaled Breath Samples: Comparative Evaluation of Storage Conditions Using HS-SPME-GC/MS.Molecules (Basel, Switzerland) · 2026
- Untargeted analysis of volatile markers of post-exercise fat oxidation in exhaled breath.Journal of breath research · 2026
- Non-Invasive Estimation of Systemic Drug Exposure Using Exhaled Breath Metabolomics in Humans: A Translational Proof-of-Concept Study.Clinical pharmacology and therapeutics · 2026