Stability of Volatile Organic Compounds in Exhaled Breath Samples: Comparative Evaluation of Storage Conditions Using HS-SPME-GC/MS.
Erica Villaroel Solis, Gonzalo Taborda Ocampo, Jorge Alberto Jaramillo Garzon
Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No 26-10, Manizales 170004, Colombia.
Key points
From the paper's conclusion- This study evaluated the stability of volatile organic compounds (VOCs) in exhaled breath samples under different storage conditions (storage at −20 °C vs. room temperature, 25 °C) and analysis times (0 h, 3 h, 6 h, and 12 h).
Abstract
This study evaluated the stability of volatile organic compounds (VOCs) in exhaled breath samples under different storage conditions (storage at -20 °C vs. room temperature, 25 °C) and analysis times (0 h, 3 h, 6 h, and 12 h). Alveolar exhaled breath samples were collected from 30 volunteers in 500 mL Tedlar® bags, followed by analysis using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). Seventy-three metabolites were putatively identified, of which 40 met the detection-frequency criterion (present in ≥70% of samples) under both conditions. After excluding two annotations considered physicochemically implausible for headspace analysis (glycine and cholesteryl benzoate), 38 common VOCs were retained. Freezing at -20 °C significantly influenced the variability of 30 of these 38 VOCs (FDR-adjusted p < 0.05). Specifically, freezing reduced the coefficient of variation (CV) of 20 of the 38 metabolites compared to samples kept at room temperature. Six metabolites, including isoprene, methoxyacetic acid, methylcyclohexane and 1-pentene, showed CV < 15% under both conditions. A quantitative drop of more than 90% of the total analytical signal was observed at room temperature by 12 h after sample collection, whereas freezing substantially attenuated, but did not fully eliminate, this signal loss. These findings highlight the influence of pre-analytical conditions on the integrity of volatile profiles, indicating that immediate cold storage is essential in breath biomarker studies. These results provide key criteria for the standardization of breathomics protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Within-day temporal dynamics of exhaled breath features during prolonged fasting monitored by SESI-HRMS: a pilot study.Talanta · 2026
- The Human Breath Volatilome Responds to Exercise and Recovery: An Untargeted Profiling Study.Journal of breath research · 2026
- Sorbent-coated metal discs: A hybrid active/passive exhaled breath sampling alternative for early lung cancer screeningJournal of Pharmaceutical and Biomedical Analysis · 2026
- Preanalytical Benchmarks for Solvent-Based GC-MS Profiling of Volatile Organic Compounds in Diabetic Foot Ulcer Swabs.Journal of the American Society for Mass Spectrometry · 2026
- The impact of benralizumab and dupilumab on exhaled volatile organic compound profiles of severe asthma patients - a preliminary analysis.Respiratory medicine · 2026
- Internal Molecular Response Chains to Inhaled Volatile Organic Compounds for Precision Health Risk Assessment Revealed by BreathomicsEnvironmental Science & Technology · 2026