Stability of Volatile Organic Compounds in Exhaled Breath Samples: Comparative Evaluation of Storage Conditions Using HS-SPME-GC/MS.

Erica Villaroel Solis, Gonzalo Taborda Ocampo, Jorge Alberto Jaramillo Garzon

Grupo de Investigación en Cromatografía y Técnicas Afines GICTA, Departamento de Química, Facultad de Ciencias Exactas y Naturales, Universidad de Caldas, Calle 65 No 26-10, Manizales 170004, Colombia.

Key points

From the paper's conclusion
  • This study evaluated the stability of volatile organic compounds (VOCs) in exhaled breath samples under different storage conditions (storage at −20 °C vs. room temperature, 25 °C) and analysis times (0 h, 3 h, 6 h, and 12 h).

Abstract

This study evaluated the stability of volatile organic compounds (VOCs) in exhaled breath samples under different storage conditions (storage at -20 °C vs. room temperature, 25 °C) and analysis times (0 h, 3 h, 6 h, and 12 h). Alveolar exhaled breath samples were collected from 30 volunteers in 500 mL Tedlar® bags, followed by analysis using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). Seventy-three metabolites were putatively identified, of which 40 met the detection-frequency criterion (present in ≥70% of samples) under both conditions. After excluding two annotations considered physicochemically implausible for headspace analysis (glycine and cholesteryl benzoate), 38 common VOCs were retained. Freezing at -20 °C significantly influenced the variability of 30 of these 38 VOCs (FDR-adjusted p < 0.05). Specifically, freezing reduced the coefficient of variation (CV) of 20 of the 38 metabolites compared to samples kept at room temperature. Six metabolites, including isoprene, methoxyacetic acid, methylcyclohexane and 1-pentene, showed CV < 15% under both conditions. A quantitative drop of more than 90% of the total analytical signal was observed at room temperature by 12 h after sample collection, whereas freezing substantially attenuated, but did not fully eliminate, this signal loss. These findings highlight the influence of pre-analytical conditions on the integrity of volatile profiles, indicating that immediate cold storage is essential in breath biomarker studies. These results provide key criteria for the standardization of breathomics protocols.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers