Untargeted analysis of volatile markers of post-exercise fat oxidation in exhaled breath.
Andre Homeyer, Júlia Blanka Sziládi, Jan-Philipp Redlich, Jonathan D Beauchamp, Y Lan Pham
Fraunhofer Institute for Digital Medicine MEVIS, Max-Von-Laue-Straße 2, Bremen, HB, 28359, Germany. · Fraunhofer Institute for Process Engineering and Packaging IVV, Giggenhauser Straße 35, Freising, BY, 85354, Germany.
Key points
From the paper's conclusion- We performed an
untargeted screening for volatile organic compounds (VOCs) that could serve
as markers of fat oxidation beyond acetone, and investigated whether breath
measurements taken during exercise could predict post-exercise changes in fat
oxidation.
Abstract
Breath acetone represents a promising non-invasive biomarker for monitoring fat oxidation during exercise. However, its utility is limited by confounding factors, as well as by the fact that significant changes in concentration occur only hours post-exercise, which makes real-time assessment difficult. We performed an untargeted screening for volatile organic compounds (VOCs) that could serve as markers of fat oxidation beyond acetone, and investigated whether breath measurements taken during exercise could predict post-exercise changes in fat oxidation. Nineteen participants completed two 25-min cycling sessions separated by a brief 5-min rest period. VOC emissions were analysed using proton-transferreaction time-of-flight mass spectrometry (PTR-TOF-MS) during exercise and after a 90-min recovery period. Blood β-hydroxybutyrate (BOHB) concentrations served as the reference marker for fat oxidation. Among 773 relevant analytical features detected in the PTR-TOF-MS measurements, only four signals exhibited strong correlations with BOHB (ρ ≥ 0.82, p = 0.0002)-all attributable to acetone or its isotopologues or fragments. End-of-exercise measurements of these signals enabled accurate prediction of participants with substantial post-exercise BOHB changes (F1 score ≥ 0.83, accuracy = 0.89). Our study did not reveal any novel breath-based biomarkers of fat oxidation, but it confirmed acetone as the key marker. Moreover, our findings suggest that breath acetone measurements during exercise may already enable basic predictions of post-exercise fat oxidation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exercise intensity alters the relationship between breath acetone output and oxygen uptake during cycling exercise: a comparison of submaximal and incremental maximal protocols.Journal of breath research · 2026
- The Human Breath Volatilome Responds to Exercise and Recovery: An Untargeted Profiling Study.Journal of breath research · 2026
- Exhaled breath acetone during rest and exercise reflects haemodynamic stress and reduced functional capacity across the heart-failure spectrumEuropean Heart Journal · 2026
- Field Evaluation of a Portable Multi-Sensor Platform for Characterizing Inter-Individual Variability in Exhaled Breath Responses.Sensors (Basel, Switzerland) · 2026
- Exercise Lactate in Post-COVID-19 Condition: Pathophysiological Signal, Phenotyping Tool, or Candidate Biomarker? A Narrative Review with a Hypothesis-Generating Clinical Observation.Current problems in cardiology · 2026
- Within-day temporal dynamics of exhaled breath features during prolonged fasting monitored by SESI-HRMS: a pilot study.Talanta · 2026