Radiography (London, England : 1995)

Evaluation of a simplified immobilization approach in thoracic SBRT: A comparative analysis of two patient positioning systems.

C Valenta, B Colson, M Mollet, J Billard, L Ettalhaoui, F Felici, C Invernizzi, S Guendouzen,

Department of Radiation Oncology, Institut Godinot, Reims, France. · Department of Radiation Oncology, Institut Godinot, Reims, France; Université de Reims Champagne-Ardenne, CRESTIC, Reims, France.

Observational · n=16

Key points

From the paper's conclusion
  • Both immobilization systems provided adequate positioning reproducibility for thoracic SBRT. Lower z-axis displacement was observed with the thermoformed chin-chest mask, although respiratory insufficiency may have contributed to this difference.

Abstract

INTRODUCTION: The choice of immobilization system in thoracic stereotactic body radiation therapy (SBRT) influences patient comfort, workflow efficiency, and position reproducibility. This study compared the reproducibility of two immobilization strategies, using a vacuum mattress alone versus a reference immobilization setup combining a vacuum mattress with a thermoformed chin-chest mask for thoracic SBRT. METHODS: This retrospective study included 16 patients treated with thoracic SBRT: 11 positioned with a vacuum mattress combined with a thermoformed chin-chest mask (control group) and 5 with a vacuum mattress alone (investigational group). All patients underwent 4DCT simulation under free-breathing conditions to assess tumor motion. Translational displacements (left-right [x], superior-inferior [y], anterior-posterior [z]) and rotational shifts (pitch, yaw, roll) were recorded over 71 treatment fractions. Statistical comparisons between the two immobilization groups were performed for patient characteristics and outcome measures using Fisher's exact test for categorical variables and Wilcoxon rank-sum tests. RESULTS: Among the 71 fractions, 70.4% were delivered using the mask-and-mattress system and 29.6% using the mattress-only setup. Patient characteristics, including age, tumor location, and body mass index, were retrospectively collected from medical records and were comparable between groups. Mean translational (0.4 cm) and rotational (1.2°) displacements were similar between groups. Displacement along the z-axis was significantly greater in the investigational group (p = 0.008), particularly for lower-lobe tumors (p = 0.005). CONCLUSION: Both immobilization systems provided adequate positioning reproducibility for thoracic SBRT. Lower z-axis displacement was observed with the thermoformed chin-chest mask, although respiratory insufficiency may have contributed to this difference. IMPLICATIONS FOR PRACTICE: A vacuum mattress alone may represent a simpler alternative for thoracic SBRT in appropriately selected patients, while additional caution may be warranted in patients with respiratory insufficiency.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Evaluation of a simplified immobilization approach in thoracic SBRT: A comparative analysis of two patient positioning systems — Science Skim