Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

Double Transeptal Puncture for SAPIEN M3 Transcatheter Mitral Valve Replacement: Initial Experience, Indications, and Technique.

Clara Fernandez-Cordon, David Hoare, Aayush Singal, Sanjeev Bhattacharyya, Suneil K Aggarwal, Michael J Mullen

Cardiology Department, Barts Heart Centre, St Bartholomew's Hospital, London, UK.

Key points

From the paper's conclusion
  • The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR).

Abstract

The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR). The transeptal guide sheath is used to deploy the dock, which is completely released before inserting and deploying the M3 valve using the same femoral access, transeptal puncture (TSP) and guide sheath. However, clinical scenarios such us low dock position or small left ventricular outflow tract (LVOT) may require to deploy the M3 valve with a second guide sheath while the dock is still attached to the first. In this article, we describe our initial experience with the "double transeptal technique" in two patients, focusing on indications and key technical points.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Double Transeptal Puncture for SAPIEN M3 Transcatheter Mitral Valve Replacement: Initial Experience, Indications, and Technique — Science Skim