Harmony™ Valve Implantation in the Right Pulmonary Artery in a Patient with Repaired Tetralogy of Fallot and Left Pulmonary Artery Occlusion: A Case Report.
Masaru Yabusaki, Saki Hasegawa, Shintaro Nakano, Takuro Kojima
Department of Pediatric Cardiology, Saitama Medical University International Medical Center, Saitama, Japan. · Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan.
Key points
From the paper's conclusion- We report a 41-year-old woman with repaired tetralogy of Fallot and complete left pulmonary artery occlusion who developed severe pulmonary regurgitation and advanced biventricular dysfunction.
Abstract
UNLABELLED: Transcatheter pulmonary valve implantation using the Harmony™ valve (Medtronic, Minneapolis, MN, USA) has expanded treatment options for pulmonary regurgitation in patients with enlarged right ventricular outflow tracts. However, complex pulmonary artery anatomy may preclude standard implantation in the main pulmonary artery. We report a 41-year-old woman with repaired tetralogy of Fallot and complete left pulmonary artery occlusion who developed severe pulmonary regurgitation and advanced biventricular dysfunction. Implantation in the main pulmonary artery was not feasible because of unfavorable anatomy and a significant pressure gradient. A 25-mm Harmony™ valve was therefore successfully implanted in the proximal right pulmonary artery, preserving branch perfusion and without creating additional pressure gradients. The patient's clinical condition stabilized without procedural complications. This case suggests that right pulmonary artery implantation of the Harmony™ valve may be a viable alternative in carefully selected patients with unilateral pulmonary artery occlusion when standard implantation is not feasible. LEARNING OBJECTIVES: This case highlights that the Harmony™ valve can be implanted in the proximal right pulmonary artery when standard main pulmonary artery implantation is not feasible. In patients with complex pulmonary artery anatomy, careful anatomical and hemodynamic assessment may enable alternative implantation strategies that preserve branch perfusion without creating additional pressure gradients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-Expandable Harmony Valve Implantation in Supravalvular Pulmonary Position After Senning Procedure: A Case Report.Pediatric cardiology · 2026
- Early Outcomes of Harmony Transcatheter Pulmonary Valve Implantation in the Middle East: A Single-Center Experience From Saudi Arabia.CJC pediatric and congenital heart disease · 2026
- Case Report: Steerable catheter- and balloon-assisted recapture of a self-expanding pulmonary valve: a novel technical solutionFrontiers in Cardiovascular Medicine · 2026
- Melody, Harmony, and Discord: A Complication During Pulmonic Valve Intervention in a Patient With Tetralogy of Fallot.Cureus · 2026
- First-in-Human Valve-in-Valve Implantation of a Self-Expanding Pulmonary Valve Within a Dysfunctional Balloon-Expandable Pulmonary Valve.JACC. Case reports · 2026
- Implantation of a Self-Expanding Transcatheter Pulmonary Valve as a Salvage Procedure After Embolization of a Prestent.JACC. Case reports · 2026